FireCADCalc

Packed Absorber: Transfer Units (Colburn) and Height

Number of overall gas-phase transfer units of a packed absorber by the Colburn equation for a straight equilibrium line, and the packed height from HOG.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 2 % to 0.1 %Lean solvent

From the packing maker or a correlation.

Results

Stripping factor mG/L0.80000
Transfer units8.6138
Packed height6.8911m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 % to 0.1 %. The inputs, in the units selected above:

InputValue
Solute in the gas entering2.0000 %
Solute in the gas leaving0.10000 %
Solute in the liquid entering0 %
Equilibrium slope y = mx1.2000 -
Liquid-to-gas molar ratio1.8000 -
Height of a transfer unit0.60000 m

Applying the formula below gives:

ResultValue
Stripping factor mG/L0.66667
Transfer units5.9773
Packed height3.5864 m

Open this example in the calculator and change any input.

Formula

\(N_{OG} = \frac{1}{1 - \lambda}\ln\left[(1 - \lambda)\frac{y_1 - m x_2}{y_2 - m x_2} + \lambda\right], \quad \lambda = \frac{mG}{L}\)

Variables

Symbol Meaning SI unit
\(y_1\) Solute in the gas entering -
\(y_2\) Solute in the gas leaving -
\(x_2\) Solute in the liquid entering -
\(m\) Equilibrium slope y = mx -
\(L/G\) Liquid-to-gas molar ratio -
\(H_{OG}\) Height of a transfer unit m
\(\lambda\) Stripping factor mG/L -
\(N_{OG}\) Transfer units -
\(Z\) Packed height m

Method and standards

Colburn.

Where it is used

  • Packed scrubbers and strippers.
  • Flue gas and vent scrubbers.

Common mistakes

  • Mass ratios for molar.
  • H_OG outside the packing's range.

Assumptions and limits

  • Dilute, isothermal, straight lines.

References

  • Colburn (1939) N_OG for straight equilibrium and operating lines; Z = H_OG × N_OG

Questions and answers

2 % to 0.1 % with m 1.2 and L/G 1.8, H_OG 0.6 m?

N_OG about 5.98: some 3.6 m of packing.

Transfer units vs stages?

They are equal only when the lines are parallel (λ = 1).

Add margin?

Add for distributors and uncertainty in H_OG.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.