FireCADCalc

ID Fan Sizing (Induced Draught Fan)

Induced draught fan design flow, pressure, power and motor from the fuel analysis, firing rate, excess air, air in-leakage and gas temperature, with the cold-start power.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalThermic fluid heatingPulp and paperASME PTC 4 (fired steam generators)BoilerStack and chimneyFan and blower

This calculator is a step of the workflow Boiler: fuel to fans: enter the data once and each step feeds the next.

Inputs

Examples: Indian coal 12 t/h, 25 % excess air, 10 % leakage, 140 °CBagasse 25 t/h, 30 % excess air, 15 % leakage, 160 °C, 2 x 50 %Fuel oil 2 t/h, 15 % excess air, 5 % leakage, 180 °C, site 0.99 bar

Ultimate analysis, as fired, by mass

Gas flow

Leakage at the air heater, casing, dust collector and ducts. Enter your design value.
20 % when the fan is sized from the boiler duty (peak load is 110 % of rating, plus wear and leakage). Default from FireCAD design practice; enter your specification's value.

Altitude (ISO 2533 standard atmosphere)

Barometric pressure entered

Pressure

Sets the gas density at the inlet.
Enter your specification's pressure margin, if any.

Fan and motor

From the fan maker at the duty point. Default from FireCAD design practice; enter your specification's value.
10 % for fan motors. Default from FireCAD design practice; enter your specification's value.

Results

Started on cold air at the same speed and flow the fan absorbs 192 kW, more than the 160 kW motor: start with the inlet damper or vanes closed, use a variable speed drive, or choose a motor that covers the cold start.

Design volume flow per fan (at the fan inlet)112,928m³/h
Design fan pressure336.51mmWC
Standard motor rating (IEC 60072-1)160.00kW
Minimum motor rating (absorbed + margin)142.34kW
Power absorbed at the design point129.40kW
Power with cold air at the same speed and flow192.10kW
Design mass flow per fan80,437kg/h
Gas density at the fan inlet0.71228kg/m³
Molar mass of the gas27.425kg/kmol
Absolute pressure at the fan inlet0.93535bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal 12 t/h, 25 % excess air, 10 % leakage, 140 °C. The inputs, in the units selected above:

InputValue
Carbon45.000 %
Hydrogen3.5000 %
Oxygen5.0000 %
Nitrogen1.0000 %
Sulphur0.50000 %
Ash35.000 %
Moisture10.000 %
Fuel firing rate at MCR12,000 kg/h
Excess air25.000 %
Air humidity (kg water per kg dry air)0.013000 kg/kg
Air in-leakage up to the fan, as a share of combustion air10.000 %
Gas temperature at the fan inlet140.00 °C
Flow margin20.000 %
Fans sharing the duty (1 = each fan 100 %)1.0000 -
Site pressure fromAltitude (ISO 2533 standard atmosphere)
Site altitude above sea level0 m
Barometric pressure at the site (absolute)1.0132 bar
Suction at the fan inlet (below barometric)203.94 mmWC
Fan pressure required at MCR (from the draught balance)254.93 mmWC
Pressure margin0 %
Fan efficiency80.000 %
Motor margin over the power absorbed10.000 %
Air temperature for the cold-start check30.000 °C

Applying the formula below gives:

ResultValue
Design volume flow per fan (at the fan inlet)157,337 m³/h
Design fan pressure254.93 mmWC
Standard motor rating (IEC 60072-1)160.00 kW
Minimum motor rating (absorbed + margin)150.23 kW
Power absorbed at the design point136.58 kW
Power with cold air at the same speed and flow183.83 kW
Design mass flow per fan133,431 kg/h
Gas density at the fan inlet0.84806 kg/m³
Molar mass of the gas29.330 kg/kmol
Absolute pressure at the fan inlet0.99325 bar

Open this example in the calculator and change any input.

Formula

Per kg of fuel, flue gas from the exact-ratio balance plus the leaking humid air:

\(\dot m_g = \dot m_f\left[m_g + l\,m_a(1+\omega)\right] \qquad \dot n_g = \dot m_f\left[n_g + l\left(\frac{m_a}{M_{da}} + \frac{m_a\,\omega}{M_w}\right)\right] \qquad M_g = \frac{\dot m_g}{\dot n_g}\)

\(p_{in} = p - \Delta p_{in} \qquad \rho_g = \frac{p_{in}\,M_g}{R\,T_g} \qquad \dot m = \dot m_g\,\frac{1 + m_Q}{n} \qquad \dot V = \frac{\dot m}{\rho_g}\)

\(\Delta p = \Delta p_{req}(1 + m_p) \qquad P_s = \frac{\dot V\,\Delta p}{\eta_f} \qquad P_{m,min} = P_s(1 + m_m) \qquad P_c = P_s\,\frac{\rho_{air}(T_c)}{\rho_g}\)

Variables

Symbol Meaning SI unit
\(C\), \(H\), \(O\), \(N\), \(S\) carbon, hydrogen, oxygen, nitrogen, sulphur in the fuel as fired –
\(A\) ash –
\(M\) moisture –
\(\dot m_f\) fuel firing rate at MCR kg/s
\(EA\) excess air –
\(\omega\) air humidity kg/kg
\(l\) air in-leakage as a share of combustion air –
\(T_g\) gas temperature at the fan inlet K
\(m_Q\) flow margin –
\(n\) fans sharing the duty –
\(\text{site}\) site pressure from altitude or entered –
\(z\) site altitude m
\(p_s\) barometric pressure entered Pa
\(\Delta p_{in}\) suction at the fan inlet Pa
\(\Delta p_{req}\) fan pressure required at MCR Pa
\(m_p\) pressure margin –
\(\eta_f\) fan efficiency –
\(m_m\) motor margin –
\(T_c\) air temperature at a cold start K
\(\dot V\) design volume flow per fan m³/s
\(\Delta p\) design fan pressure Pa
\(P_{std}\) standard motor rating W
\(P_{m,min}\) minimum motor rating W
\(P_s\) power absorbed W
\(P_c\) power on cold air at the same speed and flow W
\(\dot m\) design mass flow per fan kg/s
\(\rho_g\) gas density at the fan inlet kg/m³
\(M_g\) molar mass of the gas kg/kmol
\(p_{in}\) absolute pressure at the fan inlet Pa
\(m_g\), \(n_g\) wet flue gas per kg of fuel, by mass and in kmol kg/kg, kmol/kg
\(m_a\) dry air per kg of fuel kg/kg
\(p\) barometric pressure Pa

Method and standards

Flue gas from the exact-ratio combustion balance with ASME PTC 4-2013 air, plus air in-leakage; ideal-gas density at the fan inlet; site pressure from ISO 2533; fan power as V Δp / η with the fan pressure and efficiency on the same basis (both total or both static), in the ISO 5801 form with the compressibility coefficient taken as 1, which slightly overstates the power at high fan pressures (a few per cent at 10 kPa); motor ratings IEC 60072-1. The cold-start power follows the fan laws at constant speed and volume (power in proportion to density). Default efficiency and margins are FireCAD design practice (owner, 2026-11-10).

Where it is used

  • Sizing induced draught fans of balanced-draught boilers.
  • Checking ID fan capacity for a fuel change, higher excess air or air heater leakage.
  • Specifying fans for ESP, bag filter and scrubber retrofits, which add pressure drop.

Common mistakes

  • Leaving out air heater and duct leakage from the gas flow.
  • Using the design gas temperature without the higher temperature of a fouled boiler.
  • Forgetting the extra draught loss of a new dust collector.

Assumptions and limits

  • Gas temperature at the fan inlet is your design value; the leaking air is taken as already mixed in at that temperature.
  • Fly ash is not part of the gas flow.
  • The cold-start check assumes the fan reaches full speed with the dampers open on ambient air; real starts are usually made with dampers closed. The cold air is taken as dry, at the same inlet pressure as the hot design case.
  • Only the mass flow carries a margin; for a fouled or aged boiler, enter the higher gas temperature yourself.

References

  • ASME PTC 4-2013 (air composition)
  • ISO 5801 (fan power)
  • ISO 2533 (site pressure)
  • IEC 60072-1 (motor ratings)

Questions and answers

How is an ID fan sized?

From the flue gas at MCR plus the air leaking in up to the fan, at the gas temperature and the pressure at the fan inlet, plus the flow margin. For 12 t/h of Indian coal at 25 % excess air with 10 % leakage at 140 °C the fan needs 43.7 m³/s; at 2.5 kPa and 80 % it absorbs 137 kW, so a 160 kW motor.

What is the cold-start check?

Started on cold air the fan moves the same volume at the same speed, but the air is denser, so it absorbs more power: 184 kW in that example, more than the motor. Start it with inlet dampers or vanes closed, use a variable speed drive, or take a larger motor.

Where does the fan pressure come from?

From the draught balance: furnace suction plus the losses of the boiler, economiser, air heater, dust collector and ducts, less the stack's natural draught.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.