Worked example
Example: GCV 4200 kcal/kg air-dried to as received: M_ar 12 %, M_ad 6 %, ash 38 % dry. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Value to convert (GCV, carbon %, ash %, volatile matter …) | 4,200.0 - |
| Basis of the value | Air-dried |
| Basis wanted | As received (as fired) |
| Total moisture, as received | 12.000 % |
| Moisture of the air-dried sample | 6.0000 % |
| Ash, dry basis | 38.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Value on the basis wanted | 3,931.9 |
| As received | 3,931.9 |
| Air-dried | 4,200.0 |
| Dry | 4,468.1 |
| Dry, ash-free | 7,206.6 |
Open this example in the calculator and change any input.
Formula
\(f_{ar} = 1 - M_{ar} \qquad f_{ad} = 1 - M_{ad} \qquad f_d = 1 \qquad f_{daf} = \frac{1}{1 - A_d}\)
\(v_d = \frac{v}{f_{from}} \qquad v_{to} = v_d\,f_{to}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v\) | value to convert | any |
| \(\text{from}\) | basis of the value | – |
| \(\text{to}\) | basis wanted | – |
| \(M_{ar}\) | total moisture, as received | – |
| \(M_{ad}\) | moisture of the air-dried sample | – |
| \(A_d\) | ash, dry basis | – |
| \(v_{to}\) | value on the basis wanted | any |
| \(v_{ar}\) | as received | any |
| \(v_{ad}\) | air-dried | any |
| \(v_d\) | dry | any |
| \(v_{daf}\) | dry, ash-free | any |
| \(f\) | factor for each basis: kg of dry fuel per kg of fuel on that basis (\(f_{daf}\): kg of dry fuel per kg of dry ash-free fuel, inverted) | – |
Method and standards
Mass balance of moisture and ash, the relations tabulated in ASTM D3180 and ISO 17246: a quantity that is zero in water scales with the dry mass, and one that is also zero in ash scales with the dry ash-free mass. Ash itself converts between as received, air-dried and dry only: on a dry ash-free basis it is zero by definition.
Where it is used
- Reading coal and biomass lab reports and supply contracts.
- Preparing as-fired analyses for combustion and efficiency calculations.
- Comparing fuels on a dry ash-free basis.
Common mistakes
- Converting NCV or moisture with these factors.
- Using air-dried moisture as total moisture.
- Giving ash on the as-received basis where dry is asked.
Assumptions and limits
- Values that are zero in water (and, for the daf basis, zero in ash): GCV, C, H excluding moisture hydrogen, N, S, O by difference on a dry basis, volatile matter. Ash converts between as received, air-dried and dry only; its daf value is meaningless (zero by definition).
- The calculator cannot tell whether hydrogen and oxygen include the moisture's H and O; enter values that exclude it.
- A result above 100 % for a percentage value is flagged as inconsistent.
References
- Basis relations of ASTM D3180 and ISO 17246 (mass balance of moisture and ash)
Questions and answers
How do I convert GCV from air-dried to as received?
Multiply by (1 − M_ar)/(1 − M_ad). Coal at 4200 kcal/kg air-dried, with 12 % total moisture and 6 % air-dried moisture, has 3932 kcal/kg as received; dry it is 4468, dry ash-free 7207.
Which basis should a boiler calculation use?
As received (as fired): that is what the boiler burns and what the scale weighs. Lab reports are often air-dried; contracts may use another basis.
Can I convert net calorific value the same way?
No: NCV subtracts the latent heat of the water, which changes with moisture. Convert the GCV, then compute the NCV on the new basis.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.