Worked example
Example: Day: 33 t coal, 200 t steam, 18.6 MJ/kg, 10.5 bar(a) sat, feed 105 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel burned in the period | 33.000 t |
| Steam generated in the period | 200.00 t |
| Gross calorific value of the fuel, as fired | 18,600 kJ/kg |
| Steam pressure (absolute) | 10.500 bar |
| Steam condition | Dry saturated |
| Steam temperature (superheated only) | 250.00 °C |
| Feedwater temperature | 105.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel per tonne of steam | 165.00 kg/t |
| Evaporation ratio (steam per kg fuel) | 6.0606 kg/kg |
| Implied boiler efficiency (on GCV, blowdown not counted) | 76.183 % |
Open this example in the calculator and change any input.
Formula
\(SFC = \frac{m_f}{m_s} \qquad ER = \frac{m_s}{m_f} \qquad \eta = \frac{m_s\,(h_s - h_{fw})}{m_f \cdot GCV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_f\) | fuel burned in the period | kg |
| \(m_s\) | steam generated in the period | kg |
| \(GCV\) | gross calorific value as fired | J/kg |
| \(p\) | steam pressure, absolute | Pa |
| \(\text{state}\) | saturated or superheated steam | – |
| \(T_s\) | steam temperature (superheated) | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(SFC\) | fuel per unit of steam | kg/kg |
| \(ER\) | evaporation ratio | kg/kg |
| \(\eta\) | implied efficiency on GCV | – |
| \(h_s\), \(h_{fw}\) | steam and feedwater enthalpy (IF97) | J/kg |
Method and standards
Input–output totals over a period; steam and feedwater enthalpies from FireCAD's IAPWS-IF97.
Where it is used
- Daily boiler house reports and fuel reconciliation.
- Spotting fuel quality or meter problems early.
- Monthly cost of steam.
Common mistakes
- Weighing fuel as received but using an air-dried calorific value.
- Ignoring stock changes in the bunker over the period.
- Using a steam meter with no pressure correction.
Assumptions and limits
- Totals over the same period; blowdown not counted in the steam, so the implied efficiency is slightly below a direct-method figure that counts it.
- Warnings appear for an implied efficiency above 95 % or below 50 %.
References
- IAPWS R7-97(2012) IF97
- input–output definitions
Questions and answers
How much coal per tonne of steam is normal?
It depends on the coal and the steam. 33 t of 18.6 MJ/kg coal making 200 t of saturated steam at 10.5 bar(a) from 105 °C feedwater is 165 kg per tonne, an evaporation ratio of 6.06 and an implied efficiency of 76.2 %.
Why compare by efficiency and not just by kg per tonne?
Kg per tonne changes with the coal's calorific value and the steam conditions. The implied efficiency removes both, so a month of wet coal does not look like a bad boiler.
Is this the same as the direct-method efficiency?
Nearly: it is the input–output efficiency from period totals instead of instantaneous flows, but without the heat in the blowdown, so it reads slightly lower than a direct-method test that counts blowdown. Use the direct-method calculator for a test at steady load.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.