FireCADCalc

CO₂ per Tonne of Steam (Fossil and Biogenic)

Fuel heat for a steam output (IF97, boiler efficiency) and fossil and biogenic CO₂ per tonne of steam from the fossil share of heat and emission factors.

Process steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Bagasse with 15 % coalAll coal

Results

IPCC defaults are on net calorific value: use a net efficiency with them. Biogenic CO₂ from bagasse is reported as a memo item.

Fuel heat input59.492MW
Fossil CO₂3.0391t/h
Fossil CO₂ per tonne of steam50.652kg/t
Biogenic CO₂ (reported separately)18.205t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bagasse with 15 % coal. The inputs, in the units selected above:

InputValue
Steam60.000 t/h
Steam pressure (absolute)46.000 bar
Steam temperature440.00 °C
Feedwater temperature105.00 °C
Boiler efficiency (on the basis of the emission factors)80.000 %
Fossil share of heat input15.000 %
Fossil emission factor94.600 t/TJ
Biogenic emission factor100.00 t/TJ

Applying the formula below gives:

ResultValue
Fuel heat input59.492 MW
Fossil CO₂3.0391 t/h
Fossil CO₂ per tonne of steam50.652 kg/t
Biogenic CO₂ (reported separately)18.205 t/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = \frac{\dot m_s (h_s - h_{fw})}{\eta}, \quad \dot m_{CO_2,f} = \dot Q f EF_f\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) Steam kg/s
\(p\) Steam pressure (absolute) Pa
\(T\) Steam temperature K
\(T_{fw}\) Feedwater temperature K
\(\eta\) Boiler efficiency (on the basis of the emission factors) -
\(f\) Fossil share of heat input -
\(EF_f\) Fossil emission factor kg/J
\(EF_b\) Biogenic emission factor kg/J
\(\dot Q\) Fuel heat input W
\(\dot m_{CO_2,f}\) Fossil CO₂ kg/s
\(e_f\) Fossil CO₂ per tonne of steam kg/kg
\(\dot m_{CO_2,b}\) Biogenic CO₂ (reported separately) kg/s

Method and standards

Energy balance: fuel heat is the heat to the steam (IAPWS-IF97 enthalpies) over the efficiency; CO₂ is the heat times each share and its emission factor.

Where it is used

  • Carbon accounting.
  • Fuel switching studies.

Common mistakes

  • Gross efficiency with net factors.

Assumptions and limits

  • Steady output.
  • All the non-fossil heat input is taken as biogenic; other non-fossil heat (electric, waste heat) must be removed from the shares first.
  • The efficiency must be on the same calorific basis as the emission factors (net for IPCC defaults).
  • Steam must be superheated and feedwater liquid at the steam pressure.

References

  • Fuel heat from IAPWS-IF97 enthalpies and efficiency; emission factors per TJ (IPCC 2006 Vol. 2 defaults as user inputs)

Questions and answers

Why separate biogenic CO₂?

Carbon from bagasse was absorbed by the cane; inventories report it apart from fossil CO₂.

Which emission factor?

Your fuel's factor, or IPCC defaults per TJ on net calorific value.

Net or gross efficiency?

Match the factors: IPCC factors are on net calorific value.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.