Worked example
Example: 78 to 82 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel rate now | 5.0000 t/h |
| Efficiency now | 78.000 % |
| Efficiency after improvement | 82.000 % |
| Operating hours per year | 8,000.0 h |
| Fuel price per tonne | 9,000.0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel rate after | 4.7561 t/h |
| Fuel saved | 0.24390 t/h |
| Fuel saved per year | 1,951.2 t |
| Cost saving per year | 1.7561e+07 |
| Fuel saving | 4.8780 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_{f,2} = \dot m_f \frac{\eta_1}{\eta_2}, \quad \frac{\Delta \dot m_f}{\dot m_f} = 1 - \frac{\eta_1}{\eta_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_f\) | Fuel rate now | kg/s |
| \(\eta_1\) | Efficiency now | - |
| \(\eta_2\) | Efficiency after improvement | - |
| \(t\) | Operating hours per year | s |
| \(c\) | Fuel price per tonne | - |
| \(\dot m_{f,2}\) | Fuel rate after | kg/s |
| \(\Delta\dot m_f\) | Fuel saved | kg/s |
| \(\Delta M\) | Fuel saved per year | kg |
| \(\Delta C\) | Cost saving per year | - |
| \(\Delta\dot m_f/\dot m_f\) | Fuel saving | - |
Method and standards
Heat balance.
Where it is used
- Energy-saving project justification.
Common mistakes
- Saving taken as η₂ − η₁.
Assumptions and limits
- Same output and fuel. If the efficiency after is lower, the result is negative: extra fuel, with a note.
References
- Same useful heat: ṁ_f2 = ṁ_f1 η₁/η₂
Questions and answers
Why is the saving more than the efficiency points?
Fuel varies with 1/η, so the saving is (η₂ − η₁)/η₂, slightly more than the points gained divided by 100.
Same basis?
Use efficiencies on the same calorific-value basis.
Currency?
Any, per tonne of fuel.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.