Worked example
Example: Day: feed pumps 2400 kWh, fans 3000 kWh, other 1100 kWh, 200 t steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed pump energy in the period | 2,400.0 kWh |
| Fan energy (FD, ID, PA, SA) in the period | 3,000.0 kWh |
| Other auxiliaries (fuel and ash handling, water treatment, lighting) | 1,100.0 kWh |
| Steam generated in the period | 200.00 t |
| Electricity price per kWh (your currency) | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Auxiliary power per tonne of steam | 32.500 kWh/t |
| Power cost per tonne of steam (your currency) | 260.00 |
| Total auxiliary energy | 6,500.0 kWh |
| Share of feed pumps | 36.923 % |
| Share of fans | 46.154 % |
Open this example in the calculator and change any input.
Formula
\(E = E_{fw} + E_{fan} + E_o \qquad SPC = \frac{E}{m_s} \qquad C_t = SPC \cdot c_e \qquad s_{fw} = \frac{E_{fw}}{E} \qquad s_{fan} = \frac{E_{fan}}{E}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_{fw}\) | feed pump energy | J |
| \(E_{fan}\) | fan energy | J |
| \(E_o\) | other auxiliary energy | J |
| \(m_s\) | steam generated | kg |
| \(c_e\) | electricity price per kWh | – |
| \(SPC\) | auxiliary energy per unit of steam | J/kg |
| \(C_t\) | power cost per tonne of steam | – |
| \(E\) | total auxiliary energy | J |
| \(s_{fw}\) | feed pump share | – |
| \(s_{fan}\) | fan share | – |
Method and standards
Energy audit definition of specific auxiliary consumption; shown in kWh per tonne (1 kWh/t = 3.6 kJ/kg).
Where it is used
- Daily and monthly boiler house reports.
- Finding the auxiliaries worth fitting with variable speed drives.
- Steam cost calculations.
Common mistakes
- Leaving out fuel handling, ash handling and water treatment.
- Comparing days with very different loads: kWh per tonne rises at low load.
- Reading energy meters over a different period than the steam meter.
Assumptions and limits
- Energy and steam totals for the same period.
References
- Energy audit definitions (auxiliary energy per unit output)
Questions and answers
How much power does a boiler house use per tonne of steam?
Feed pumps 2400 kWh, fans 3000 kWh and other auxiliaries 1100 kWh for 200 t of steam is 32.5 kWh per tonne; at 8 per kWh that adds 260 to the cost of each tonne. Fans take 46 % and feed pumps 37 %.
What is a good figure?
It depends on fuel, pressure and draught system: oil and gas shell boilers use little, coal and biomass boilers with ID fans, mills and ash handling use much more. Track your own trend and compare similar plants.
Where are the savings?
Usually in fans and pumps on damper or valve control: variable speed drives, correct excess air and fewer leaks cut both.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.