FD Fan Sizing (Forced Draught Fan)

Forced draught fan design flow, pressure, power and motor from the fuel analysis, firing rate, excess air, air-side resistances and site conditions.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalThermic fluid heatingPulp and paperASME PTC 4 (fired steam generators)BoilerBurner and furnaceFan and blower

This calculator is a step of the workflow Boiler: fuel to fans: enter the data once and each step feeds the next.

Inputs

Examples: Indian coal 12 t/h, 25 % excess air, sea level, 1 x 100 %Bagasse 25 t/h, 30 % excess air, site 450 m, 2 x 50 %, pressure margin 10 %Fuel oil 2 t/h, 15 % excess air, site 0.99 bar

Ultimate analysis, as fired, by mass

Air flow

The highest summer temperature gives the largest volume.
20 % when the fan is sized from the boiler duty (peak load is 110 % of rating, plus wear and leakage). Default from FireCAD design practice; enter your specification's value.

Altitude (ISO 2533 standard atmosphere)

Barometric pressure entered

Resistance at MCR

Enter your specification's pressure margin, if any.

Fan and motor

From the fan maker at the duty point. Default from FireCAD design practice; enter your specification's value.
10 % for fan motors. Default from FireCAD design practice; enter your specification's value.

Results

Design volume flow per fan (at the fan inlet)34,281m³/h
Design fan pressure244.73mmWC
Standard motor rating (IEC 60072-1 to 1000 kW, R20 series above)37.000kW
Minimum motor rating (absorbed + margin)33.519kW
Power absorbed at the design point30.472kW
Design mass flow per fan (wet air)38,700kg/h
Air density at the fan inlet1.1289kg/m³
Barometric pressure used0.99000bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal 12 t/h, 25 % excess air, sea level, 1 x 100 %. The inputs, in the units selected above:

InputValue
Carbon45.000 %
Hydrogen3.5000 %
Oxygen5.0000 %
Nitrogen1.0000 %
Sulphur0.50000 %
Ash35.000 %
Moisture10.000 %
Fuel firing rate at MCR12,000 kg/h
Excess air25.000 %
Air humidity (kg water per kg dry air)0.013000 kg/kg
Air temperature at the fan inlet35.000 °C
Flow margin20.000 %
Fans sharing the duty (1 = each fan 100 %)1.0000 -
Site pressure fromAltitude (ISO 2533 standard atmosphere)
Site altitude above sea level0 m
Barometric pressure at the site (absolute)1.0132 bar
Air heater, air side122.37 mmWC
Ducts, dampers and silencer61.183 mmWC
Burner, windbox or grate and bed152.96 mmWC
Pressure margin0 %
Fan efficiency80.000 %
Motor margin over the power absorbed10.000 %

Applying the formula below gives:

ResultValue
Design volume flow per fan (at the fan inlet)99,230 m³/h
Design fan pressure336.51 mmWC
Standard motor rating (IEC 60072-1 to 1000 kW, R20 series above)132.00 kW
Minimum motor rating (absorbed + margin)125.07 kW
Power absorbed at the design point113.70 kW
Design mass flow per fan (wet air)112,792 kg/h
Air density at the fan inlet1.1367 kg/m³
Barometric pressure used1.0132 bar

Open this example in the calculator and change any input.

Formula

\(\dot m = \dot m_f\,m_a\,(1+\omega)\,\frac{1 + m_Q}{n} \qquad \rho = \frac{(1+\omega)\,p}{\left(\frac{1}{M_{da}} + \frac{\omega}{M_w}\right) R\,T_a} \qquad \dot V = \frac{\dot m}{\rho}\)

\(\Delta p = (\Delta p_{ah} + \Delta p_d + \Delta p_b)(1 + m_p) \qquad P_s = \frac{\dot V\,\Delta p}{\eta_f} \qquad P_{m,min} = P_s\,(1 + m_m)\)

\(m_a\) is the dry air per kg of fuel from the exact-ratio combustion balance; \(P_{std}\) is the next IEC 60072-1 rating; \(p\) is the barometric pressure from ISO 2533 or entered.

Variables

Symbol Meaning SI unit
\(C\), \(H\), \(O\), \(N\), \(S\) carbon, hydrogen, oxygen, nitrogen, sulphur in the fuel as fired –
\(A\) ash –
\(M\) moisture –
\(\dot m_f\) fuel firing rate at MCR kg/s
\(EA\) excess air –
\(\omega\) air humidity, kg water per kg dry air kg/kg
\(T_a\) air temperature at the fan inlet K
\(m_Q\) flow margin –
\(n\) fans sharing the duty –
\(\text{site}\) site pressure from altitude or entered –
\(z\) site altitude m
\(p_s\) barometric pressure entered Pa
\(\Delta p_{ah}\) air heater, air side Pa
\(\Delta p_{d}\) ducts, dampers and silencer Pa
\(\Delta p_{b}\) burner, windbox or grate and bed Pa
\(m_p\) pressure margin –
\(\eta_f\) fan efficiency –
\(m_m\) motor margin –
\(\dot V\) design volume flow per fan m³/s
\(\Delta p\) design fan pressure Pa
\(P_{std}\) standard motor rating W
\(P_{m,min}\) minimum motor rating W
\(P_s\) power absorbed W
\(\dot m\) design mass flow per fan kg/s
\(\rho\) air density at the fan inlet kg/m³
\(p\) barometric pressure used Pa
\(m_a\) dry air per kg of fuel kg/kg
\(M_{da}\), \(M_w\) molar mass of dry air and water kg/kmol
\(R\) universal gas constant, 8314.46 (per kmol, to match \(M\) in kg/kmol) J/(kmol·K)

Method and standards

Combustion air from the exact-ratio balance with the ASME PTC 4-2013 air composition; humid-air density by the ideal-gas law; site pressure from ISO 2533; fan power as defined in ISO 5801; motor ratings from IEC 60072-1. Default efficiency and margins are FireCAD design practice (owner, 2026-11-10).

Where it is used

  • Sizing forced draught fans for burners, grates and fluidised beds.
  • Checking an FD fan for a fuel change or higher site temperature.
  • Specifying fans for high-altitude sites.

Common mistakes

  • Using standard air density at a hot or high-altitude site.
  • Forgetting air heater leakage, which the FD fan must also supply.
  • Taking the burner pressure only and missing the air heater, ducts and dampers.

Assumptions and limits

  • Resistances at MCR flow; the pressure margin covers fouling and uncertainty if your specification asks for it.
  • Air heater leakage to the gas side is not added to the FD fan flow; add it to the excess air if the air heater leaks significantly.
  • Incompressible fan power; above about 5 kPa the true power is slightly lower (ISO 5801).
  • The air is for complete combustion of all the fuel carbon (no unburnt-carbon deduction); the fan inlet static pressure is taken as the barometric pressure.
  • The site altitude is used as the geopotential altitude of ISO 2533; the difference from height above sea level is negligible below 5000 m.
  • Motor ratings follow IEC 60072-1 up to 1000 kW and an R20 preferred-number series above.

References

  • ASME PTC 4-2013 (air composition)
  • ISO 5801 (fan power)
  • ISO 2533 (site pressure)
  • IEC 60072-1 (motor ratings)

Questions and answers

How is an FD fan sized?

From the combustion air at MCR (fuel analysis and excess air), plus the flow margin, at the density of the hottest summer air at site. For 12 t/h of Indian coal at 25 % excess air and 35 °C the fan needs 27.6 m³/s; at 3.3 kPa and 80 % efficiency it absorbs 114 kW, so a 132 kW motor.

Which margins are applied?

The flow margin (default 20 %) and motor margin (default 10 %) are FireCAD design practice; a pressure margin is your input. All three are input boxes; your specification overrides them.

Why does altitude matter?

The fan moves volume. At altitude the air is thinner, so the same mass of combustion air needs more volume; at 450 m the volume is about 5 % larger than at sea level.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.