FireCADCalc

Adiabatic Flame Temperature Calculator

Adiabatic flame temperature of coal, oil or biomass from its ultimate analysis, excess air, air preheat and calorific value, by a flue gas enthalpy balance (NIST).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalBoilerBurner and furnace

Inputs

Examples: Indian coal, 25 % excess air, air 30 °CFuel oil, 15 %, air 200 °CBagasse 50 % moisture, 30 %, air 200 °C

Ultimate analysis, as fired, by mass

Results

No dissociation: above about 1800 °C real flames are cooler because CO₂ and H₂O dissociate. Ash heat is neglected.

Adiabatic flame temperature1,695.9°C
Net calorific value used17,592kJ/kg
Wet flue gas per kg of fuel8.4828kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal, 25 % excess air, air 30 °C. The inputs, in the units selected above:

InputValue
Carbon45.000 %
Hydrogen3.5000 %
Oxygen5.0000 %
Nitrogen1.0000 %
Sulphur0.50000 %
Ash35.000 %
Moisture10.000 %
Excess air25.000 %
Air humidity (kg water per kg dry air)0.013000 kg/kg
Gross calorific value, as fired18,600 kJ/kg
Combustion air temperature30.000 °C

Applying the formula below gives:

ResultValue
Adiabatic flame temperature1,695.9 °C
Net calorific value used17,592 kJ/kg
Wet flue gas per kg of fuel8.4828 kg/kg

Open this example in the calculator and change any input.

Formula

\(m_g\,[h_g(T_{ad}) - h_g(T_0)] = NCV + m_a\,[h_a(T_a) - h_a(T_0)] + m_w\,[h_v(T_a) - h_v(T_0)], \quad T_0 = 25\ ^\circ\mathrm{C}\)

\(NCV = GCV - h_{fg,25}\,\left(\frac{M_{H_2O}}{M_{H_2}}\,H + M\right)\)

Variables

Symbol Meaning SI unit
\(C, H, O, N, S, A, M\) ultimate analysis as fired –
\(EA\) excess air –
\(\omega\) air humidity kg/kg
\(GCV\) gross calorific value J/kg
\(T_a\) air temperature K
\(T_{ad}\) adiabatic flame temperature K
\(NCV\) net calorific value J/kg
\(m_g\) wet flue gas per kg fuel kg/kg
\(m_a\) dry air per kg fuel kg/kg
\(m_w\) air moisture per kg fuel kg/kg
\(h_g, h_a, h_v\) enthalpies of flue gas, dry air and vapour (Shomate) J/kg
\(T_0\) reference temperature K
\(h_{fg,25}\) latent heat of water at 25 °C (IF97) J/kg
\(M_{H_2O}, M_{H_2}\) molar masses of water and hydrogen (ratio about 8.94) kg/kmol

Method and standards

Exact-ratio combustion balance and NIST Shomate enthalpies of the products and air; fuel enters at 25 °C; NCV from GCV with the IF97 latent heat at 25 °C; solved for the temperature where products hold all the heat.

Where it is used

  • Comparing fuels, excess air and air preheat.
  • Furnace design and NOx tendency studies.
  • Teaching combustion.

Common mistakes

  • Using GCV instead of NCV.
  • Expecting the real furnace to reach this temperature.
  • Ignoring dissociation above about 1800 °C.

Assumptions and limits

  • Complete combustion, no dissociation, no heat loss; ash heat neglected.

References

  • NIST Chemistry WebBook Shomate equations
  • Energy balance of combustion (no dissociation)

Questions and answers

How hot is a coal flame?

Coal with 18.6 MJ/kg GCV at 25 % excess air and 30 °C air reaches about 1696 °C adiabatically (no heat loss, no dissociation).

Why does excess air lower it?

The same heat warms more gas. Preheating the air does the opposite, which is why hot air helps wet fuels burn.

Is the real furnace this hot?

No: the furnace walls absorb heat at once, and above about 1800 °C dissociation lowers peak temperatures. It is an upper bound and a comparison figure.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.