Worked example
Example: Indian coal, 25 % excess air, air 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Carbon | 45.000 % |
| Hydrogen | 3.5000 % |
| Oxygen | 5.0000 % |
| Nitrogen | 1.0000 % |
| Sulphur | 0.50000 % |
| Ash | 35.000 % |
| Moisture | 10.000 % |
| Excess air | 25.000 % |
| Air humidity (kg water per kg dry air) | 0.013000 kg/kg |
| Gross calorific value, as fired | 18,600 kJ/kg |
| Combustion air temperature | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Adiabatic flame temperature | 1,695.9 °C |
| Net calorific value used | 17,592 kJ/kg |
| Wet flue gas per kg of fuel | 8.4828 kg/kg |
Open this example in the calculator and change any input.
Formula
\(m_g\,[h_g(T_{ad}) - h_g(T_0)] = NCV + m_a\,[h_a(T_a) - h_a(T_0)] + m_w\,[h_v(T_a) - h_v(T_0)], \quad T_0 = 25\ ^\circ\mathrm{C}\)
\(NCV = GCV - h_{fg,25}\,\left(\frac{M_{H_2O}}{M_{H_2}}\,H + M\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C, H, O, N, S, A, M\) | ultimate analysis as fired | – |
| \(EA\) | excess air | – |
| \(\omega\) | air humidity | kg/kg |
| \(GCV\) | gross calorific value | J/kg |
| \(T_a\) | air temperature | K |
| \(T_{ad}\) | adiabatic flame temperature | K |
| \(NCV\) | net calorific value | J/kg |
| \(m_g\) | wet flue gas per kg fuel | kg/kg |
| \(m_a\) | dry air per kg fuel | kg/kg |
| \(m_w\) | air moisture per kg fuel | kg/kg |
| \(h_g, h_a, h_v\) | enthalpies of flue gas, dry air and vapour (Shomate) | J/kg |
| \(T_0\) | reference temperature | K |
| \(h_{fg,25}\) | latent heat of water at 25 °C (IF97) | J/kg |
| \(M_{H_2O}, M_{H_2}\) | molar masses of water and hydrogen (ratio about 8.94) | kg/kmol |
Method and standards
Exact-ratio combustion balance and NIST Shomate enthalpies of the products and air; fuel enters at 25 °C; NCV from GCV with the IF97 latent heat at 25 °C; solved for the temperature where products hold all the heat.
Where it is used
- Comparing fuels, excess air and air preheat.
- Furnace design and NOx tendency studies.
- Teaching combustion.
Common mistakes
- Using GCV instead of NCV.
- Expecting the real furnace to reach this temperature.
- Ignoring dissociation above about 1800 °C.
Assumptions and limits
- Complete combustion, no dissociation, no heat loss; ash heat neglected.
References
- NIST Chemistry WebBook Shomate equations
- Energy balance of combustion (no dissociation)
Questions and answers
How hot is a coal flame?
Coal with 18.6 MJ/kg GCV at 25 % excess air and 30 °C air reaches about 1696 °C adiabatically (no heat loss, no dissociation).
Why does excess air lower it?
The same heat warms more gas. Preheating the air does the opposite, which is why hot air helps wet fuels burn.
Is the real furnace this hot?
No: the furnace walls absorb heat at once, and above about 1800 °C dissociation lowers peak temperatures. It is an upper bound and a comparison figure.