Worked example
Example: Indian coal 35 % ash, fly 2 %, bottom 6 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ash in the fuel, as fired | 35.000 % |
| Share of ash leaving as fly ash | 80.000 % |
| Carbon in fly ash (carbon analysis; LOI overstates it) | 2.0000 % |
| Carbon in bottom ash (carbon analysis; LOI overstates it) | 6.0000 % |
| Gross calorific value of the fuel, as fired | 18,600 kJ/kg |
| Fuel firing rate (for the loss in kW) | 50,000 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Unburned carbon loss, % of heat input | 1.8463 % |
| Heat lost in unburned carbon | 4,769.7 kW |
| Unburned carbon | 509.12 kg/h |
| Unburned carbon per kg of fuel | 0.010182 kg/kg |
Open this example in the calculator and change any input.
Formula
\(m_C = A\,x_f\,\frac{c_f}{1 - c_f} + A\,(1 - x_f)\,\frac{c_b}{1 - c_b}\)
\(L_C = \frac{m_C \cdot HHV_C}{GCV} \qquad \dot m_C = \dot m_f\,m_C \qquad \dot Q_C = \dot m_C \cdot HHV_C\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | ash in fuel, as fired | – |
| \(x_f\) | share of ash leaving as fly ash | – |
| \(c_f\) | carbon in fly ash | – |
| \(c_b\) | carbon in bottom ash | – |
| \(GCV\) | gross calorific value of the fuel | J/kg |
| \(\dot m_f\) | fuel firing rate | kg/s |
| \(L_C\) | unburned carbon loss, fraction of input | – |
| \(m_C\) | unburned carbon per kg of fuel | kg/kg |
| \(\dot m_C\) | unburned carbon flow | kg/s |
| \(\dot Q_C\) | heat lost in unburned carbon | W |
| \(HHV_C\) | heating value of carbon, 14 500 Btu/lb = 33.73 MJ/kg (PTC 4) | J/kg |
Method and standards
Unburned carbon loss as in ASME PTC 4 §5.14: carbon in the residue times the higher heating value of carbon, 14 500 Btu/lb, divided by the fuel's gross calorific value. Indian practice (IS 8753) uses the same equation.
Where it is used
- Efficiency tests and audits of coal, lignite, biomass and fluidised-bed boilers.
- Tuning mills (coal fineness) and secondary air to bring fly-ash carbon down.
- Judging whether fly ash is saleable to cement plants, which limit its loss on ignition.
- Comparing grate, pulverised-fuel and fluidised-bed boilers on combustion completeness.
Common mistakes
- Using the carbon percentage on the residue as if it were per kg of fuel.
- Ignoring the bottom ash: in grate and stoker boilers it often holds more carbon than the fly ash.
- Using a pulverised-fuel fly-ash share (about 80 %) for a grate boiler, where it may be 20–40 %.
- Taking LOI as carbon in a fluidised bed with limestone, where carbonates inflate it.
Assumptions and limits
- All unburned combustible in the residue is carbon. Enter the carbon from a carbon analysis of each ash; loss on ignition overstates it (carbonates, sulphur).
- Fly-ash share and carbon contents are averages over the test.
References
- ASME PTC 4-2013 Fired Steam Generators §5.14 (unburned carbon in residue)
- BIS IS 8753 (boiler efficiency)
Questions and answers
How do I calculate unburned carbon loss?
Find the carbon leaving in each ash per kg of fuel and multiply by the heating value of carbon. Coal with 35 % ash, 80 % of it as fly ash at 2 % carbon and bottom ash at 6 % carbon, leaves 10.2 g of carbon per kg of fuel, a loss of 1.85 % at 18.6 MJ/kg.
Why divide by (1 − carbon)?
The carbon percentage is measured on the residue, which is ash plus carbon. The ash per kg of fuel is fixed, so the residue is A/(1 − c) and its carbon A·c/(1 − c).
Is LOI the same as carbon?
Close but not equal. Loss on ignition also counts carbonates and some sulphur, so it overstates the carbon a little, especially with limestone in a fluidised bed. A carbon analysis is more accurate.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.