FireCADCalc

Unburned Carbon Loss (Carbon in Ash)

Boiler efficiency loss from unburned carbon in fly ash and bottom ash, from the fuel ash, the fly-ash share and the carbon in each ash (ASME PTC 4).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileASME PTC 4 (fired steam generators)BoilerDust collector (ESP, bag filter, cyclone)

Inputs

Examples: Indian coal 35 % ash, fly 2 %, bottom 6 %Imported coal 12 % ash, fly 3 %, bottom 8 %Bagasse 2 % ash, fly 15 %, bottom 25 %

Results

Unburned carbon loss, % of heat input1.5544%
Heat lost in unburned carbon1,047.1kW
Unburned carbon111.76kg/h
Unburned carbon per kg of fuel0.004471kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal 35 % ash, fly 2 %, bottom 6 %. The inputs, in the units selected above:

InputValue
Ash in the fuel, as fired35.000 %
Share of ash leaving as fly ash80.000 %
Carbon in fly ash (carbon analysis; LOI overstates it)2.0000 %
Carbon in bottom ash (carbon analysis; LOI overstates it)6.0000 %
Gross calorific value of the fuel, as fired18,600 kJ/kg
Fuel firing rate (for the loss in kW)50,000 kg/h

Applying the formula below gives:

ResultValue
Unburned carbon loss, % of heat input1.8463 %
Heat lost in unburned carbon4,769.7 kW
Unburned carbon509.12 kg/h
Unburned carbon per kg of fuel0.010182 kg/kg

Open this example in the calculator and change any input.

Formula

\(m_C = A\,x_f\,\frac{c_f}{1 - c_f} + A\,(1 - x_f)\,\frac{c_b}{1 - c_b}\)

\(L_C = \frac{m_C \cdot HHV_C}{GCV} \qquad \dot m_C = \dot m_f\,m_C \qquad \dot Q_C = \dot m_C \cdot HHV_C\)

Variables

Symbol Meaning SI unit
\(A\) ash in fuel, as fired –
\(x_f\) share of ash leaving as fly ash –
\(c_f\) carbon in fly ash –
\(c_b\) carbon in bottom ash –
\(GCV\) gross calorific value of the fuel J/kg
\(\dot m_f\) fuel firing rate kg/s
\(L_C\) unburned carbon loss, fraction of input –
\(m_C\) unburned carbon per kg of fuel kg/kg
\(\dot m_C\) unburned carbon flow kg/s
\(\dot Q_C\) heat lost in unburned carbon W
\(HHV_C\) heating value of carbon, 14 500 Btu/lb = 33.73 MJ/kg (PTC 4) J/kg

Method and standards

Unburned carbon loss as in ASME PTC 4 §5.14: carbon in the residue times the higher heating value of carbon, 14 500 Btu/lb, divided by the fuel's gross calorific value. Indian practice (IS 8753) uses the same equation.

Where it is used

  • Efficiency tests and audits of coal, lignite, biomass and fluidised-bed boilers.
  • Tuning mills (coal fineness) and secondary air to bring fly-ash carbon down.
  • Judging whether fly ash is saleable to cement plants, which limit its loss on ignition.
  • Comparing grate, pulverised-fuel and fluidised-bed boilers on combustion completeness.

Common mistakes

  • Using the carbon percentage on the residue as if it were per kg of fuel.
  • Ignoring the bottom ash: in grate and stoker boilers it often holds more carbon than the fly ash.
  • Using a pulverised-fuel fly-ash share (about 80 %) for a grate boiler, where it may be 20–40 %.
  • Taking LOI as carbon in a fluidised bed with limestone, where carbonates inflate it.

Assumptions and limits

  • All unburned combustible in the residue is carbon. Enter the carbon from a carbon analysis of each ash; loss on ignition overstates it (carbonates, sulphur).
  • Fly-ash share and carbon contents are averages over the test.

References

  • ASME PTC 4-2013 Fired Steam Generators §5.14 (unburned carbon in residue)
  • BIS IS 8753 (boiler efficiency)

Questions and answers

How do I calculate unburned carbon loss?

Find the carbon leaving in each ash per kg of fuel and multiply by the heating value of carbon. Coal with 35 % ash, 80 % of it as fly ash at 2 % carbon and bottom ash at 6 % carbon, leaves 10.2 g of carbon per kg of fuel, a loss of 1.85 % at 18.6 MJ/kg.

Why divide by (1 − carbon)?

The carbon percentage is measured on the residue, which is ash plus carbon. The ash per kg of fuel is fixed, so the residue is A/(1 − c) and its carbon A·c/(1 − c).

Is LOI the same as carbon?

Close but not equal. Loss on ignition also counts carbonates and some sulphur, so it overstates the carbon a little, especially with limestone in a fluidised bed. A carbon analysis is more accurate.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.