Grate Area from Fuel Burning Rate

Grate area a solid-fuel boiler needs from the fuel burnt per hour and the burning rate per m² of grate, with the grate heat release and the grate length for a width.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerBurner and furnaceBoiler attendant and boiler operator examinations

Inputs

Examples: 1 t/h coal at 150 kg/(m²·h), 4 000 kcal/kg, 2 m wide3 t/h bagasse at 400 kg/(m²·h), 2 270 kcal/kg, 4 m wide500 kg/h wood at 120, 3 000 kcal/kg, 1.5 m

Your figure for the fuel and grate type; it decides the area.

Results

Grate area4.1667m²
Grate length for the width2.7778m
Heat release per m² of grate418.68kW/m²
Heat input of the fuel1,744.5kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 t/h coal at 150 kg/(m²·h), 4 000 kcal/kg, 2 m wide. The inputs, in the units selected above:

InputValue
Fuel burnt1,000.0 kg/h
Burning rate per m² of grate0.041667 kg/(m²·s)
Calorific value of the fuel (GCV or NCV, as your grate limit is quoted)16,747 kJ/kg
Grate width2.0000 m

Applying the formula below gives:

ResultValue
Grate area6.6667 m²
Grate length for the width3.3333 m
Heat release per m² of grate697.80 kW/m²
Heat input of the fuel4,652.0 kW

Open this example in the calculator and change any input.

Formula

\(A_g = \frac{\dot m_f}{r_b}, \quad L_g = \frac{A_g}{B}\)

\(q_g = r_b\, GCV, \quad \dot Q = \dot m_f\, GCV\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) Fuel burnt kg/s
\(r_b\) Burning rate per m² of grate kg/(m²·s)
\(GCV\) Calorific value of the fuel J/kg
\(B\) Grate width m
\(A_g\) Grate area m²
\(L_g\) Grate length for the width m
\(q_g\) Heat release per m² of grate W/m²
\(\dot Q\) Heat input of the fuel W

Method and standards

Grate area from the fuel to be burnt and the permitted burning rate.

Worked example

A boiler burns 1000 kg/h of coal of 4000 kcal/kg; the grate can burn 150 kg/(m²·h) and is 2 m wide.

  • Area = 1000 / 150 = 6.67 m²; length = 6.67 / 2 = 3.33 m
  • Heat release = 150 × 4000 = 600 000 kcal/(h·m²) = 698 kW/m²

Where it is used

  • Boiler attendant examinations.
  • Sizing or checking stoker grates.
  • Converting a boiler to another fuel.

Common mistakes

  • Using the steam output instead of fuel burnt.
  • Using a burning rate for the wrong fuel or grate type.
  • Mixing per hour and per second.

Assumptions and limits

  • Burning rate entered by the user.
  • Whole grate area active.
  • The heat release is on the calorific basis you enter (gross or net); compare it only with limits on the same basis.
  • The burning rate is not checked against typical values for the grate type; take it from the grate maker.

References

  • Grate loading (textbook)

Questions and answers

What grate burns 1 t/h of coal at 150 kg/(m²·h)?

6.67 m²; on a 2 m wide grate, 3.33 m long. At 4000 kcal/kg the grate releases 698 kW/m² (600 000 kcal/(h·m²)).

Where does the burning rate come from?

The grate maker or practice for the fuel: it depends on the grate type, fuel size and air. It is your input.

And for bagasse?

Much higher rates are used on bagasse grates: 3 t/h at 400 kg/(m²·h) needs 7.5 m².

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.