Fire-Tube Boiler Heating Surface and Evaporation Rate

Heating surface of a fire-tube (smoke-tube) boiler from its tubes and furnace, and the evaporation per square metre of heating surface for a steam output.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerBoiler attendant and boiler operator examinations

Inputs

Examples: 120 tubes 57 mm x 4.5 m, 900 mm furnace, 3 m² other, 5 t/h80 tubes 51 mm x 3.5 m, 750 mm furnace, 2 t/hTwo-pass, 200 tubes 63.5 mm x 5 m, 1.2 m furnace, 10 t/h

Tubes

Furnace

Results

Tube heating surface n π d_t L_t44.862m²
Furnace heating surface π D_f L_f8.2467m²
Total heating surface54.609m²
Evaporation per m² of heating surface0.010173kg/(m²·s)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 120 tubes 57 mm x 4.5 m, 900 mm furnace, 3 m² other, 5 t/h. The inputs, in the units selected above:

InputValue
Number of smoke tubes120.00 -
Tube inside diameter (fire side)57.000 mm
Tube length4.5000 m
Furnace inside diameter900.00 mm
Furnace length4.5000 m
Other heated surface (reversal chamber, tube plates)3.0000 m²
Steam output5,000.0 kg/h

Applying the formula below gives:

ResultValue
Tube heating surface n π d_t L_t96.698 m²
Furnace heating surface π D_f L_f12.723 m²
Total heating surface112.42 m²
Evaporation per m² of heating surface0.012354 kg/(m²·s)

Open this example in the calculator and change any input.

Formula

\(A = n\, \pi\, d_t\, L_t + \pi\, D_f\, L_f + A_x\)

\(e = \frac{\dot m_s}{A}\)

Variables

Symbol Meaning SI unit
\(n\) Number of smoke tubes -
\(d_t\) Tube inside diameter (fire side) m
\(L_t\) Tube length m
\(D_f\) Furnace inside diameter m
\(L_f\) Furnace length m
\(A_x\) Other heated surface (reversal chamber, tube plates) m²
\(\dot m_s\) Steam output kg/s
\(A_t\) Tube heating surface n π d_t L_t m²
\(A_f\) Furnace heating surface π D_f L_f m²
\(A\) Total heating surface m²
\(e\) Evaporation per m² of heating surface kg/(m²·s)

Method and standards

Geometric area of the heated surfaces on the gas side.

Worked example

A boiler has 120 smoke tubes of 57 mm bore and 4.5 m length, a 900 mm furnace 4.5 m long and 3 m² of other heated surface; it makes 5 t/h.

  • Tubes: 120 × π × 0.057 × 4.5 = 96.7 m²
  • Furnace: π × 0.9 × 4.5 = 12.7 m²
  • Total = 112.4 m²; evaporation = 5000 / 112.4 = 44.5 kg/(m²·h)

Where it is used

  • Boiler attendant examinations.
  • Comparing boilers and checking a nameplate rating.
  • Registration papers list the heating surface.

Common mistakes

  • Using outside diameter of smoke tubes (the gas is inside).
  • Counting the water side.
  • Mixing mm and m.

Assumptions and limits

  • Plain tubes; corrugated furnaces counted by their mean diameter.
  • Other surfaces entered by the user.
  • Heating surface measured on the side touched by the hot gas: inside the smoke tubes and inside the furnace.

References

  • Fire-side area of tubes and furnace (geometry)

Questions and answers

What heating surface do 120 tubes of 57 mm bore, 4.5 m long, and a 900 mm furnace give?

Tubes 96.7 m², furnace 12.7 m², with 3 m² of other surfaces 112.4 m². At 5 t/h that is 44.5 kg of steam per m² per hour.

Which diameter is used?

The side touched by the hot gases: inside the smoke tubes and inside the furnace tube.

Why does heating surface matter?

It sets how much heat the boiler can take in, and in India the boiler attendant's certificate class depends on the heating surface of the boilers in charge. For that purpose the regulation's own definition of heating surface governs (which side and which parts count); this calculator gives the gas-side geometric area.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.