Worked example
Example: 2 t/h at 10.5 bar(a) saturated, feed 80 °C, 415 V. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam output | 2,000.0 kg/h |
| Steam pressure (absolute) | 10.500 bar |
| Steam condition | Dry saturated |
| Superheated steam temperature | 250.00 °C |
| Feedwater temperature | 80.000 °C |
| Boiler efficiency (heat loss from the shell) | 98.000 % |
| Supply line voltage | 415.00 V |
| Power factor | 100.00 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Electrical power | 1,385.0 kW |
| Line current (three-phase) | 1,926.9 A |
| Heat to the steam | 1,357.3 kW |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_s (h_s - h_{fw}) \qquad P = \frac{\dot Q}{\eta} \qquad I = \frac{P}{\sqrt{3}\,V\cos\varphi}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam output | kg/s |
| \(p\) | steam pressure | Pa |
| \(\text{state}\) | saturated or superheated | – |
| \(T_s\) | steam temperature | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(\eta\) | boiler efficiency | – |
| \(V\) | line voltage | V |
| \(\cos\varphi\) | power factor | – |
| \(P\) | electrical power | W |
| \(I\) | line current | A |
| \(\dot Q\) | heat to steam | W |
| \(h_s, h_{fw}\) | enthalpies (IF97) | J/kg |
Method and standards
Steam heat from FireCAD's IAPWS-IF97; three-phase balanced load.
Where it is used
- Sizing electric boilers and their supply.
- Comparing electric and fuel-fired steam cost.
- Power-to-heat projects.
Common mistakes
- Forgetting the feedwater temperature in the kW.
- Using phase voltage for current.
- Ignoring the supply's demand charge.
Assumptions and limits
- Balanced three-phase load; steady output.
- Blowdown heat is not included. Electrode boilers hold the water conductivity by blowdown, which carries saturated water away; add its share to the output if significant.
References
- IAPWS R7-97 IF97
- Three-phase power P = √3 V I cos φ
Questions and answers
How many kW does an electric boiler need?
2 t/h of saturated steam at 10.5 bar(a) from 80 °C feedwater takes 1.36 MW of heat; at 98 % efficiency the boiler draws 1385 kW, 1930 A at 415 V.
Why use electrode boilers?
At medium voltage they reach tens of MW with no combustion, no stack and very fast response; they suit cheap or renewable power.
Is efficiency really 98 %?
Almost all the power becomes heat; the loss is the shell's heat to the room.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.