Worked example
Example: 8 000 Nm³/h purge, 60 s, 200 °C, 24 starts a day. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Purge air flow (normal: 0 °C, 101.325 kPa) | 8,000.0 Nm³/h |
| Purge time per start (pre-purge plus post-purge) | 60.000 s |
| Mean temperature of the air leaving the boiler during purge | 200.00 °C |
| Air temperature at the fan inlet | 30.000 °C |
| Burner starts per day | 24.000 - |
| Operating days per year | 330.00 - |
| Boiler efficiency (to turn the heat into fuel) | 88.000 % |
| Fuel cost per GJ of fuel heat (your currency) | 900.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air mass per purge | 172.31 kg |
| Heat lost per purge | 29,671 kJ |
| Heat lost per year | 235.00 GJ |
| Fuel heat per year to replace it | 267.04 GJ |
| Fuel cost per year | 240,337 |
Open this example in the calculator and change any input.
Formula
\(m_a = \dot V_N\, \rho_N\, t_p\)
\(Q_p = m_a \int_{T_a}^{T_g} c_p\, dT\)
\(Q_y = Q_p\, n\, N_d, \quad Q_F = Q_y / \eta, \quad C_y = Q_F\, c_F\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_N\) | Purge air flow at normal conditions (0 °C, 101.325 kPa) | Nm³/s |
| \(t_p\) | Purge time per start (pre-purge plus post-purge) | s |
| \(T_g\) | Mean temperature of the air leaving the boiler during purge | K |
| \(T_a\) | Air temperature at the fan inlet | K |
| \(n\) | Burner starts per day | - |
| \(N_d\) | Operating days per year | - |
| \(\eta\) | Boiler efficiency (to turn the heat into fuel) | - |
| \(c_F\) | Fuel cost per GJ of fuel heat (your currency) | - |
| \(m_a\) | Air mass per purge | kg |
| \(Q_p\) | Heat lost per purge | J |
| \(Q_y\) | Heat lost per year | J |
| \(Q_F\) | Fuel heat per year to replace it | J |
| \(C_y\) | Fuel cost per year | - |
| \(\rho_N\) | Density of dry air at normal conditions (0 °C, 101.325 kPa) | kg/Nm³ |
| \(c_p\) | Specific heat of air | J/(kg·K) |
Method and standards
Each start draws a purge volume of fresh air through the furnace and passes, cooling the hot boiler. The heat is the air mass times its enthalpy rise from fan inlet to boiler outlet (NIST Shomate dry-air enthalpy). The yearly loss scales with starts per day and days in service; dividing by efficiency gives the fuel that replaces it. The purge flow and time are inputs: NFPA 85 and EN 746-2 set the purge (air changes before ignition) as applied by the burner maker; this calculator does not compute them.
Where it is used
- Justifying a burner with wider turndown or modulating control.
- Comparing one large boiler cycling with two smaller ones.
- Estimating savings from boiler sequencing.
Common mistakes
- Using the full-load stack temperature: during purge the outlet temperature falls.
- Forgetting post-purge after each stop.
- Counting only the purge: standby losses between firing also grow with cycling.
Assumptions and limits
- Dry air, steady flow during purge. The flow is at normal conditions (0 °C, 101.325 kPa); a US standard flow at 60 °F is about 5.5 % less air for the same number.
- Radiation and standby losses not included.
References
- NFPA 85 / EN 746-2 purge requirement (air changes before ignition)
- NIST Shomate air enthalpy (PTC 4 air composition)
Questions and answers
How much heat does one purge take away?
8 000 Nm³/h of air for 60 s is about 172 kg of air; heated from 30 °C to 200 °C it carries 29.7 MJ out of the boiler.
Is that significant over a year?
At 24 starts a day for 330 days it is 235 GJ of heat, or 267 GJ of fuel at 88 % efficiency, which costs about 240 000 at 900 per GJ.
How do I cut cycling losses?
Reduce the number of starts: a burner with wider turndown, modulating control, a properly sized boiler or sequencing of several boilers so one runs at low fire instead of cycling.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.