Worked example
Example: 50 t/h, drum 70 bar(a), deaerator 1.2 bar(a), 2 x 100 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Boiler steam output at MCR | 50,000 kg/h |
| Blowdown, as a share of steam | 2.0000 % |
| Flow margin | 20.000 % |
| Pumps sharing the duty (1 = each pump 100 %) | 1.0000 - |
| Drum pressure for pump sizing (absolute) | 70.000 bar |
| Economiser pressure drop | 200.00 kPa |
| Feed control valve pressure drop | 400.00 kPa |
| Discharge piping, fittings and check-valve losses | 150.00 kPa |
| Drum water level above the pump centreline | 25.000 m |
| Deaerator pressure (absolute) | 1.2000 bar |
| Deaerator water level above the pump centreline | 12.000 m |
| Suction line friction loss | 0.60000 m |
| Head margin | 0 % |
| Pump efficiency | 68.000 % |
| Motor margin over the power absorbed | 18.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Design flow per pump | 64.093 m³/h |
| Design total head | 828.42 m |
| Standard motor rating (IEC 60072-1) | 250.00 kW |
| Minimum motor rating (absorbed + margin) | 239.66 kW |
| Power absorbed at the design point | 203.10 kW |
| Design mass flow per pump | 61,200 kg/h |
| Pump discharge pressure (absolute) | 79.841 bar |
| Pump suction pressure (absolute) | 2.2675 bar |
| Feedwater density at deaerator saturation | 954.87 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\dot m = \frac{\dot m_{MCR}\,(1 + b)\,(1 + m_Q)}{n} \qquad Q = \frac{\dot m}{\rho}\)
\(p_1 = p_{da} + \rho g\,(z_{da} - h_{fs}) \qquad p_{req} = p_{dr} + \Delta p_{eco} + \Delta p_v + \Delta p_l + \rho g\,z_{dr}\)
\(H = \frac{p_{req} - p_1}{\rho g}\,(1 + m_H) \qquad p_2 = p_1 + \rho g H \qquad P_s = \frac{\dot m\,g\,H}{\eta_p} \qquad P_{m,min} = P_s\,(1 + m_m)\)
\(P_{std}\) is the next IEC 60072-1 standard rating at or above \(P_{m,min}\).
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{MCR}\) | boiler steam output at MCR | kg/s |
| \(b\) | blowdown as a share of steam | – |
| \(m_Q\) | flow margin | – |
| \(n\) | pumps sharing the duty | – |
| \(p_{dr}\) | drum pressure for sizing, absolute | Pa |
| \(\Delta p_{eco}\) | economiser pressure drop | Pa |
| \(\Delta p_{v}\) | feed control valve pressure drop | Pa |
| \(\Delta p_{l}\) | discharge piping and fitting losses | Pa |
| \(z_{dr}\) | drum level above the pump centreline | m |
| \(p_{da}\) | deaerator pressure, absolute | Pa |
| \(z_{da}\) | deaerator water level above the pump centreline | m |
| \(h_{fs}\) | suction line friction loss | m |
| \(m_H\) | head margin | – |
| \(\eta_p\) | pump efficiency | – |
| \(m_m\) | motor margin | – |
| \(Q\) | design flow per pump | m³/s |
| \(H\) | design total head | m |
| \(P_{std}\) | standard motor rating | W |
| \(P_{m,min}\) | minimum motor rating | W |
| \(P_s\) | power absorbed | W |
| \(\dot m\) | design mass flow per pump | kg/s |
| \(p_2\) | pump discharge pressure | Pa |
| \(p_1\) | pump suction pressure | Pa |
| \(\rho\) | feedwater density, saturated at the deaerator pressure | kg/m³ |
| \(p_{req}\) | pressure needed at the pump discharge | Pa |
| \(g\) | standard gravity, 9.806 65 | m/s² |
Method and standards
Pressure balance from the deaerator to the drum, with head and power as defined in ANSI/HI 1.6. Feedwater density from FireCAD's IAPWS-IF97 for saturated water at the deaerator pressure. Motor ratings from the IEC 60072-1 series. Default efficiency, margins and flow allowance are FireCAD design practice (owner, 2026-11-10); all are inputs.
Where it is used
- Specifying boiler feed pumps for drum, once-through and shell boilers.
- Checking an existing pump for a boiler uprating or a change in pressure.
- Motor selection for feed pumps.
Common mistakes
- Taking the drum pressure as the pump head and forgetting the economiser, control valve and line losses.
- Adding flow margin twice: once on the steam flow and again on the pump.
- Forgetting recirculation (minimum flow) and blowdown flow in the pump capacity.
Assumptions and limits
- Feedwater saturated at the deaerator pressure; the density change through the pump is neglected.
- The discharge pressure drops are at the design flow; enter them at that flow.
- Minimum-flow recirculation, balancing-device leak-off and attemperator spray taken from the pump discharge add to the flow: include them in the margin or the MCR.
- Check NPSH separately with the deaerator elevation calculator.
References
- ANSI/HI 1.6 (head and power definitions)
- IAPWS R7-97(2012) IF97 (feedwater density)
- IEC 60072-1 (motor ratings)
Questions and answers
How is a boiler feed pump sized?
Flow = MCR × (1 + blowdown) × (1 + flow margin), divided among the pumps sharing the duty. The discharge must reach the drum at its highest safety-valve set pressure plus the economiser, control valve and line losses and the static height. For a 50 t/h boiler at 70 bar(a) this gives 64 m³/h at 828 m head, 203 kW absorbed at 68 % and a 250 kW motor.
Why the safety-valve set pressure?
The pump must keep feeding the boiler while the safety valves lift, so the drum pressure for sizing is usually the highest set pressure. Use the value your specification or boiler code requires.
Where do the 20 % flow margin and 18 % motor margin come from?
They are FireCAD design-practice defaults (peak load is about 110 % of rating, plus wear). Every margin is an input; your specification overrides them.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.