Worked example
Example: Illustrative: slope 0.0018 cm2/mJ, eps 1650 L/(mol cm) at 254 nm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluence-based rate constant (−slope of ln C/C₀ against dose) | 0.001800 - |
| Molar absorption coefficient (decadic), L/(mol·cm) | 1,650.0 - |
| Wavelength | 254.00 nm |
| Log reduction of interest | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Quantum yield per energy, mol/mJ | 4.7378e-10 |
| Energy of one einstein (mole) of photons | 470.97 kJ/mol |
| Quantum yield, mol/einstein | 0.22313 |
| UV dose for the log reduction | 1,279.2 mJ/cm² |
Open this example in the calculator and change any input.
Formula
\(\Phi_m = \frac{k_f}{2.303\,\varepsilon}, \quad E_{einstein} = \frac{N_Ahc}{\lambda}, \quad \Phi = \Phi_mE_{einstein}\)
\(H = \frac{2.303\,LRV}{k_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_f\) | Fluence-based rate constant (−slope of ln C/C₀ against dose) | - |
| \(\varepsilon\) | Molar absorption coefficient (decadic), L/(mol·cm) | - |
| \(\lambda\) | Wavelength | m |
| \(LRV\) | Log reduction of interest | - |
| \(\Phi_m\) | Quantum yield per energy, mol/mJ | - |
| \(E_{einstein}\) | Energy of one einstein (mole) of photons | J/mol |
| \(\Phi\) | Quantum yield, mol/einstein | - |
| \(H\) | UV dose for the log reduction | J/m² |
Method and standards
Direct photolysis in optically thin bench samples.
Where it is used
- Characterising photolysis of micropollutants.
- Inputs for UV reactor design.
Common mistakes
- Using absorbance in place of the molar absorption coefficient.
- Mixing base-10 and natural logs in the slope.
Assumptions and limits
- Optically thin sample, monochromatic light.
References
- Quantum yield from the fluence-based rate constant Φ = k_f/(2.303ε) and the photon energy N_A hc/λ
Questions and answers
What is a typical quantum yield?
NDMA about 0.3 mol/einstein; many pesticides 0.01–0.1; values above 1 point to chain reactions.
Why two forms of the yield?
Bench tests give it per unit of UV energy (mol/mJ); dividing by the photon energy turns it into the classical mol per einstein.
What do the defaults represent?
An illustrative test: ln(C/C₀) falls by 0.0018 per mJ/cm² for a compound with ε 1650 L/(mol·cm) at 254 nm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 8-4, Example 8-11