FireCADCalc

Quantum Yield from a UV Bench Test (Fluence-Based Rate Constant)

Quantum yield of a compound from the slope of ln(C/C₀) against UV fluence in a collimated-beam test, its molar absorption coefficient and the wavelength.

Inputs

Examples: Illustrative: slope 0.0018 cm2/mJ, eps 1650 L/(mol cm) at 254 nmAtrazine-like compound: slope 0.0004, eps 3860, 2 log

Accepted: 1E-6 to 1
Accepted: 1 to 100,000
Accepted: 200 to 400 nm
Accepted: 0.1 to 6

Results

Φ = k_f/(2.303 ε) with k_f in cm²/mJ and ε in L/(mol·cm); one einstein (a mole of photons) carries N_A hc/λ of energy, 471 kJ at 254 nm.

Quantum yield per energy, mol/mJ4.5005e-11
Energy of one einstein (mole) of photons470.97kJ/mol
Quantum yield, mol/einstein0.021196
UV dose for the log reduction11,513mJ/cm²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: slope 0.0018 cm2/mJ, eps 1650 L/(mol cm) at 254 nm. The inputs, in the units selected above:

InputValue
Fluence-based rate constant (−slope of ln C/C₀ against dose)0.001800 -
Molar absorption coefficient (decadic), L/(mol·cm)1,650.0 -
Wavelength254.00 nm
Log reduction of interest1.0000 -

Applying the formula below gives:

ResultValue
Quantum yield per energy, mol/mJ4.7378e-10
Energy of one einstein (mole) of photons470.97 kJ/mol
Quantum yield, mol/einstein0.22313
UV dose for the log reduction1,279.2 mJ/cm²

Open this example in the calculator and change any input.

Formula

\(\Phi_m = \frac{k_f}{2.303\,\varepsilon}, \quad E_{einstein} = \frac{N_Ahc}{\lambda}, \quad \Phi = \Phi_mE_{einstein}\)

\(H = \frac{2.303\,LRV}{k_f}\)

Variables

Symbol Meaning SI unit
\(k_f\) Fluence-based rate constant (−slope of ln C/C₀ against dose) -
\(\varepsilon\) Molar absorption coefficient (decadic), L/(mol·cm) -
\(\lambda\) Wavelength m
\(LRV\) Log reduction of interest -
\(\Phi_m\) Quantum yield per energy, mol/mJ -
\(E_{einstein}\) Energy of one einstein (mole) of photons J/mol
\(\Phi\) Quantum yield, mol/einstein -
\(H\) UV dose for the log reduction J/m²

Method and standards

Direct photolysis in optically thin bench samples.

Where it is used

  • Characterising photolysis of micropollutants.
  • Inputs for UV reactor design.

Common mistakes

  • Using absorbance in place of the molar absorption coefficient.
  • Mixing base-10 and natural logs in the slope.

Assumptions and limits

  • Optically thin sample, monochromatic light.

References

  • Quantum yield from the fluence-based rate constant Φ = k_f/(2.303ε) and the photon energy N_A hc/λ

Questions and answers

What is a typical quantum yield?

NDMA about 0.3 mol/einstein; many pesticides 0.01–0.1; values above 1 point to chain reactions.

Why two forms of the yield?

Bench tests give it per unit of UV energy (mol/mJ); dividing by the photon energy turns it into the classical mol per einstein.

What do the defaults represent?

An illustrative test: ln(C/C₀) falls by 0.0018 per mJ/cm² for a compound with ε 1650 L/(mol·cm) at 254 nm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 8-4, Example 8-11

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.