Chemical Blending: Static Mixer or Pipe Length for a Target COV

Intensity of segregation for a chemical dose, the mixer length-to-diameter ratio needed for a target coefficient of variation, blending time and head loss.

Inputs

Examples: Full-scale: 2 mg/L chlorine from 120 g/L hypochlorite, Kenics 0.6 m, 0.4 m3/sFluoride into an empty 0.9 m pipe, COV 10 %

Accepted: 0.01 to 1,000 mg/L
Accepted: 0.01 to 2,000 g/L
Accepted: 0.1 to 50 %
Accepted: 5 to 5,000 mm
Accepted: 0.06 to 3,000,000 L/min
Accepted: 0 to 20

Results

(σ_b/σ_u) after L/D = (σ_b/σ_u at L/D = 1)^(L/D) with Godfrey's values; head loss = N_VH × (L/D) velocity heads. To move a sample point in a channel with a measured COV, use the empty-pipe value with σ_b/σ_u = COV_new/COV_old and the depth as D.

Volume fraction of the feed1.6666e-05
Required uniformity ratio2.0412e-04
Intensity of segregation4.1667e-08
Length-to-diameter ratio required18.390
Number of inserts13.000
Length-to-diameter ratio provided19.500
Mixer length11.700m
Velocity1.4147m/s
Blending time8.2702s
Head loss3.9797m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Full-scale: 2 mg/L chlorine from 120 g/L hypochlorite, Kenics 0.6 m, 0.4 m3/s. The inputs, in the units selected above:

InputValue
Chemical dose2.0000 mg/L
Strength of the chemical feed120.00 g/L
Target coefficient of variation5.0000 %
Mixing device (Godfrey)Kenics static mixer (0.63, 2.0)
Mixer or pipe diameter600.00 mm
Water flow24,000 L/min
Length of one mixer insert in diameters (0 for continuous length)1.5000 -

Applying the formula below gives:

ResultValue
Volume fraction of the feed1.6666e-05
Required uniformity ratio2.0412e-04
Intensity of segregation4.1667e-08
Length-to-diameter ratio required18.390
Number of inserts13.000
Length-to-diameter ratio provided19.500
Mixer length11.700 m
Velocity1.4147 m/s
Blending time8.2702 s
Head loss3.9797 m

Open this example in the calculator and change any input.

Formula

\(X_A = \frac{C_{dose}}{C_A + C_{dose}}, \quad \frac{\sigma_b}{\sigma_u} = \frac{COV\cdot X_A}{\sqrt{X_A(1 - X_A)}}, \quad I_s = \left(\frac{\sigma_b}{\sigma_u}\right)^2\)

\(\frac{L}{D} = \frac{\ln(\sigma_b/\sigma_u)}{\ln(\sigma_b/\sigma_u)_{AR=1}}, \quad H_L = N_{VH}\frac{L}{D}\frac{v^2}{2g}, \quad t_b = \frac{L}{v}\)

Variables

Symbol Meaning SI unit
\(C_{dose}\) Chemical dose kg/m³
\(C_A\) Strength of the chemical feed kg/m³
\(COV\) Target coefficient of variation -
\(\text{device}\) Mixing device (Godfrey) -
\(D\) Mixer or pipe diameter m
\(Q\) Water flow m³/s
\(L_{ins}/D\) Length of one mixer insert in diameters (0 for continuous length) -
\(X_A\) Volume fraction of the feed -
\((\sigma_b/\sigma_u)\) Required uniformity ratio -
\(I_s\) Intensity of segregation -
\(L/D\) Length-to-diameter ratio required -
\(n\) Number of inserts -
\(L/D_{used}\) Length-to-diameter ratio provided -
\(L\) Mixer length m
\(v\) Velocity m/s
\(t_b\) Blending time s
\(H_L\) Head loss m

Method and standards

Godfrey's exponential decay of segregation with mixer length.

Where it is used

  • Coagulant, fluoride and chlorine dosing.
  • Locating analyser sample points.

Common mistakes

  • Sampling before the chemical is blended.
  • Ignoring the head loss of static mixers at full scale.

Assumptions and limits

  • Turbulent flow; Godfrey's device constants.

Questions and answers

Why does the feed strength matter?

A strong feed is a tiny volume fraction to spread through the flow; the weaker the starting uniformity, the more mixing length is needed.

Static mixer or empty pipe?

An empty pipe needs about 30 diameters to cut the COV five-fold; a static mixer does it in a few diameters at a higher head loss.

What do the defaults represent?

An illustrative case: Full-scale: 2 mg/L chlorine from 120 g/L hypochlorite, Kenics 0.6 m, 0.4 m3/s. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 6-10, eqs. 6-142 to 6-159, Table 6-8 and Examples 6-11 to 6-13 (Godfrey 1985)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.