FireCADCalc

Rapid Small-Scale Column Test (RSSCT) Design for GAC

Scales a full-scale GAC adsorber to a rapid small-scale column test: EBCT, velocity, run time, bed length, flow, carbon mass and water volume.

Inputs

Examples: Same, proportional diffusivity (X = 1)Full-scale 12x40 GAC (1.3 mm), 15 min EBCT, 12 m/h, 1 year, 0.15 mm RSSCT

Accepted: 0.1 to 5 mm
Accepted: 0.01 to 3 mm
Accepted: 0.16667 to 600 min
Accepted: 0.36 to 72 m/h
Accepted: 0.041667 to 1,157.4 d
Accepted: 1 to 100 mm
Accepted: 200 to 800 kg/m³
Accepted: 0 to 1

Results

EBCT and run time scale with (d_SC/d_LC)^(2−X); the velocity scales with d_LC/d_SC to keep the Reynolds number equal. With X = 0 (constant diffusivity) the Stanton, Peclet and Reynolds numbers are all matched.

With X > 0 the Reynolds number cannot be matched as well; a lower RSSCT velocity (Re_SC ≥ 0.1) may be used to limit head loss, keeping the scaled EBCT.

Time scale factor0.21000
RSSCT empty-bed contact time2.1000min
RSSCT superficial velocity (Re matched)23.810m/h
RSSCT run time21.000d
RSSCT bed length83.333cm
RSSCT flow37.712mL/min
GAC mass in the RSSCT38.805g
Water volume needed1,140.4L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same, proportional diffusivity (X = 1). The inputs, in the units selected above:

InputValue
Full-scale (large column) GAC particle diameter1.0000 mm
RSSCT GAC particle diameter0.21000 mm
Full-scale empty-bed contact time10.000 min
Full-scale superficial velocity5.0000 m/h
Full-scale run time to simulate100.00 d
RSSCT column diameter11.000 mm
GAC bulk density490.00 kg/m³
Diffusivity exponent (0 constant, 1 proportional to particle size)1.0000 -

Applying the formula below gives:

ResultValue
Time scale factor0.21000
RSSCT empty-bed contact time2.1000 min
RSSCT superficial velocity (Re matched)23.810 m/h
RSSCT run time21.000 d
RSSCT bed length83.333 cm
RSSCT flow37.712 mL/min
GAC mass in the RSSCT38.805 g
Water volume needed1,140.4 L

Open this example in the calculator and change any input.

Formula

\(\frac{EBCT_{SC}}{EBCT_{LC}} = \frac{t_{SC}}{t_{LC}} = \left(\frac{d_{SC}}{d_{LC}}\right)^{2 - X}, \quad \frac{v_{SC}}{v_{LC}} = \frac{d_{LC}}{d_{SC}}\)

\(L_{SC} = v_{SC}EBCT_{SC}, \quad Q_{SC} = v_{SC}\frac{\pi D_{SC}^2}{4}, \quad M_{SC} = Q_{SC}EBCT_{SC}\rho_b, \quad V_W = Q_{SC}t_{SC}\)

Variables

Symbol Meaning SI unit
\(d_{LC}\) Full-scale (large column) GAC particle diameter m
\(d_{SC}\) RSSCT GAC particle diameter m
\(EBCT_{LC}\) Full-scale empty-bed contact time s
\(v_{LC}\) Full-scale superficial velocity m/s
\(t_{LC}\) Full-scale run time to simulate s
\(D_{SC}\) RSSCT column diameter m
\(\rho_b\) GAC bulk density kg/m³
\(X\) Diffusivity exponent (0 constant, 1 proportional to particle size) -
\((d_{SC}/d_{LC})^{2-X}\) Time scale factor -
\(EBCT_{SC}\) RSSCT empty-bed contact time s
\(v_{SC}\) RSSCT superficial velocity (Re matched) m/s
\(t_{SC}\) RSSCT run time s
\(L_{SC}\) RSSCT bed length m
\(Q_{SC}\) RSSCT flow m³/s
\(M_{SC}\) GAC mass in the RSSCT kg
\(V_W\) Water volume needed m³

Method and standards

Dimensional-similarity scaling of a GAC column to crushed carbon in a small column.

Where it is used

  • Planning GAC treatability tests.
  • Estimating carbon usage before a pilot plant.

Common mistakes

  • Scaling velocity with EBCT instead of with particle size.
  • Using too small a column diameter.

Assumptions and limits

  • Intraparticle diffusion controls; same carbon crushed for the RSSCT.

Questions and answers

Constant or proportional diffusivity?

Constant diffusivity (X = 0) suits many synthetic organics; proportional diffusivity (X = 1) often fits better where NOM fouling dominates. Run both if unsure.

What do the defaults represent?

An illustrative case: Same, proportional diffusivity (X = 1). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 15-6, eqs. 15-222 to 15-229 and Examples 15-14 and 15-15 (Crittenden et al. 1986, 1991)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.