Worked example
Example: Same, proportional diffusivity (X = 1). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Full-scale (large column) GAC particle diameter | 1.0000 mm |
| RSSCT GAC particle diameter | 0.21000 mm |
| Full-scale empty-bed contact time | 10.000 min |
| Full-scale superficial velocity | 5.0000 m/h |
| Full-scale run time to simulate | 100.00 d |
| RSSCT column diameter | 11.000 mm |
| GAC bulk density | 490.00 kg/m³ |
| Diffusivity exponent (0 constant, 1 proportional to particle size) | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Time scale factor | 0.21000 |
| RSSCT empty-bed contact time | 2.1000 min |
| RSSCT superficial velocity (Re matched) | 23.810 m/h |
| RSSCT run time | 21.000 d |
| RSSCT bed length | 83.333 cm |
| RSSCT flow | 37.712 mL/min |
| GAC mass in the RSSCT | 38.805 g |
| Water volume needed | 1,140.4 L |
Open this example in the calculator and change any input.
Formula
\(\frac{EBCT_{SC}}{EBCT_{LC}} = \frac{t_{SC}}{t_{LC}} = \left(\frac{d_{SC}}{d_{LC}}\right)^{2 - X}, \quad \frac{v_{SC}}{v_{LC}} = \frac{d_{LC}}{d_{SC}}\)
\(L_{SC} = v_{SC}EBCT_{SC}, \quad Q_{SC} = v_{SC}\frac{\pi D_{SC}^2}{4}, \quad M_{SC} = Q_{SC}EBCT_{SC}\rho_b, \quad V_W = Q_{SC}t_{SC}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_{LC}\) | Full-scale (large column) GAC particle diameter | m |
| \(d_{SC}\) | RSSCT GAC particle diameter | m |
| \(EBCT_{LC}\) | Full-scale empty-bed contact time | s |
| \(v_{LC}\) | Full-scale superficial velocity | m/s |
| \(t_{LC}\) | Full-scale run time to simulate | s |
| \(D_{SC}\) | RSSCT column diameter | m |
| \(\rho_b\) | GAC bulk density | kg/m³ |
| \(X\) | Diffusivity exponent (0 constant, 1 proportional to particle size) | - |
| \((d_{SC}/d_{LC})^{2-X}\) | Time scale factor | - |
| \(EBCT_{SC}\) | RSSCT empty-bed contact time | s |
| \(v_{SC}\) | RSSCT superficial velocity (Re matched) | m/s |
| \(t_{SC}\) | RSSCT run time | s |
| \(L_{SC}\) | RSSCT bed length | m |
| \(Q_{SC}\) | RSSCT flow | m³/s |
| \(M_{SC}\) | GAC mass in the RSSCT | kg |
| \(V_W\) | Water volume needed | m³ |
Method and standards
Dimensional-similarity scaling of a GAC column to crushed carbon in a small column.
Where it is used
- Planning GAC treatability tests.
- Estimating carbon usage before a pilot plant.
Common mistakes
- Scaling velocity with EBCT instead of with particle size.
- Using too small a column diameter.
Assumptions and limits
- Intraparticle diffusion controls; same carbon crushed for the RSSCT.
Questions and answers
Constant or proportional diffusivity?
Constant diffusivity (X = 0) suits many synthetic organics; proportional diffusivity (X = 1) often fits better where NOM fouling dominates. Run both if unsure.
What do the defaults represent?
An illustrative case: Same, proportional diffusivity (X = 1). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 15-6, eqs. 15-222 to 15-229 and Examples 15-14 and 15-15 (Crittenden et al. 1986, 1991)