FireCADCalc

RO Concentration Polarisation Factor and Membrane Wall Concentration

Mass transfer coefficient in a spiral-wound feed channel, the concentration polarisation factor and the solute concentration at the membrane surface.

Inputs

Examples: Lead element 30 LMH at 0.10 m/s, NaCl 2,000 mg/L (D 1.5e-9)Seawater 15 LMH, 0.2 m/s, 35,000 mg/L, 25 C

Accepted: 0.01 to 1 m/s
Accepted: 0.1 to 5 mm
Accepted: 0.36 to 360 L/(m²·h)
Accepted: 1 to 100,000 mg/L
Accepted: 1E-11 to 1E-8 m²/s
Accepted: 0.01 to 5
Accepted: 950 to 1,100 kg/m³
Accepted: 0.2 to 3 mPa·s

Results

High-rejection form β = exp(J_w/k). Manufacturers limit β to about 1.2 per element to control scaling and fouling at the membrane surface.

Hydraulic diameter (2h)1.7200mm
Reynolds number366.58
Schmidt number625.61
Mass transfer coefficient0.067119mm/s
Concentration polarisation factor1.0640
Concentration at the membrane surface37,242mg/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Lead element 30 LMH at 0.10 m/s, NaCl 2,000 mg/L (D 1.5e-9). The inputs, in the units selected above:

InputValue
Feed channel velocity0.10000 m/s
Feed channel height (spacer)0.71000 mm
Permeate flux30.000 L/(m²·h)
Bulk solute concentration2,000.0 mg/L
Solute diffusivity in water1.5000e-09 m²/s
Correlation coefficient0.47000 -
Water density998.00 kg/m³
Water viscosity1.0000 mPa·s

Applying the formula below gives:

ResultValue
Hydraulic diameter (2h)1.4200 mm
Reynolds number141.72
Schmidt number668.00
Mass transfer coefficient0.051666 mm/s
Concentration polarisation factor1.1750
Concentration at the membrane surface2,350.1 mg/L

Open this example in the calculator and change any input.

Formula

\(Re = \frac{\rho vd_H}{\mu}, \quad Sc = \frac{\mu}{\rho D_L}, \quad k_{CP} = a\frac{D_L}{d_H}Re^{0.5}Sc^{1/3}\)

\(\beta = \frac{C_M}{C_F} = \exp\left(\frac{J_w}{k_{CP}}\right)\)

Variables

Symbol Meaning SI unit
\(v\) Feed channel velocity m/s
\(h\) Feed channel height (spacer) m
\(J_w\) Permeate flux m/s
\(C_F\) Bulk solute concentration kg/m³
\(D_L\) Solute diffusivity in water m²/s
\(a\) Correlation coefficient -
\(\rho\) Water density kg/m³
\(\mu\) Water viscosity Pa·s
\(d_H\) Hydraulic diameter (2h) m
\(Re\) Reynolds number -
\(Sc\) Schmidt number -
\(k_{CP}\) Mass transfer coefficient m/s
\(\beta\) Concentration polarisation factor -
\(C_M\) Concentration at the membrane surface kg/m³

Method and standards

Film theory of concentration polarisation with a spacer-channel mass transfer correlation.

Where it is used

  • Checking element flux limits.
  • Scaling risk at the membrane surface.

Common mistakes

  • Using the channel height instead of 2h as the hydraulic diameter.
  • Ignoring polarisation when computing osmotic pressure.

Assumptions and limits

Questions and answers

Why does polarisation matter?

The higher wall concentration raises osmotic pressure (cutting flux), raises salt passage and brings sparingly soluble salts closer to scaling.

How do I reduce it?

Lower flux or higher cross-flow velocity; lead elements with high flux are the most affected.

What do the defaults represent?

An illustrative case: Lead element 30 LMH at 0.10 m/s, NaCl 2,000 mg/L (D 1.5e-9). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 17-5, eqs. 17-33, 17-35 and 17-37 to 17-41 and Example 17-3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.