Worked example
Example: Small plant 0.2 m3/s, 1.5 m/h, two 8 x 3.5 m basins, 20 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Design (maximum day) flow | 0.20000 m³/s |
| Average flow | 0.15000 m³/s |
| Overflow rate (critical settling velocity) | 1.5000 m/h |
| Number of basins | 2.0000 - |
| Basin width | 8.0000 m |
| Water depth | 3.5000 m |
| Flow channels per basin (longitudinal baffles + 1) | 1.0000 - |
| Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) | 1.0000 mPa·s |
| Water density | 998.20 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total surface area | 480.00 m² |
| Basin length | 30.000 m |
| Length to width ratio | 3.7500 |
| Length to depth ratio | 8.5714 |
| Detention time at design flow | 2.3333 h |
| Detention time at average flow | 3.1111 h |
| Horizontal velocity | 0.21429 m/min |
| Hydraulic radius of a channel | 1.8667 m |
| Reynolds number (keep below 20,000) | 6,654.7 |
| Froude number (keep above 10⁻⁵) | 6.9678e-07 |
Open this example in the calculator and change any input.
Formula
\(A = \frac{Q}{v_c}, \quad L = \frac{A}{n_bW}, \quad v_f = \frac{Q}{n_bWh}\)
\(R_h = \frac{(W/n_c)h}{W/n_c + 2h}, \quad Re = \frac{\rho v_fR_h}{\mu}, \quad Fr = \frac{v_f^2}{gR_h}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Design (maximum day) flow | m³/s |
| \(Q_{avg}\) | Average flow | m³/s |
| \(v_c\) | Overflow rate (critical settling velocity) | m/s |
| \(n_b\) | Number of basins | - |
| \(W\) | Basin width | m |
| \(h\) | Water depth | m |
| \(n_c\) | Flow channels per basin (longitudinal baffles + 1) | - |
| \(\mu\) | Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) | Pa·s |
| \(\rho\) | Water density | kg/m³ |
| \(A\) | Total surface area | m² |
| \(L\) | Basin length | m |
| \(L/W\) | Length to width ratio | - |
| \(L/h\) | Length to depth ratio | - |
| \(t_d\) | Detention time at design flow | s |
| \(t_{avg}\) | Detention time at average flow | s |
| \(v_f\) | Horizontal velocity | m/s |
| \(R_h\) | Hydraulic radius of a channel | m |
| \(Re\) | Reynolds number (keep below 20,000) | - |
| \(Fr\) | Froude number (keep above 10⁻⁵) | - |
Method and standards
Ideal-basin overflow rate design with hydraulic stability checks.
Where it is used
- Sizing conventional sedimentation for a new plant.
- Checking existing basins at a new capacity.
Common mistakes
- Designing on average flow.
- Ignoring the Froude criterion in wide, shallow basins.
Assumptions and limits
- Ideal settling at the overflow rate; even flow distribution.
Questions and answers
Why check the Froude number?
A very low Froude number means inertia is weak against gravity, so temperature or density differences can short-circuit the basin; narrower channels raise it.
Why design on the maximum day flow?
The basin must still settle the floc on the worst day; at average flow the detention is longer and performance better.
What do the defaults represent?
An illustrative case: Small plant 0.2 m3/s, 1.5 m/h, two 8 x 3.5 m basins, 20 C. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 10-6, eqs. 10-17, 10-32 and 10-33, Table 10-4 and Example 10-6