FireCADCalc

Plate (Lamella) Settler: Critical Settling Velocity by Flow Pattern

Fluid velocity between inclined plates and the smallest settling velocity fully removed for counter-current, co-current or cross-flow plate settlers.

Inputs

Examples: Same pack, co-current at 75 degCross-flow 1.5 m plates, 80 mm, 55 deg, 400 m3/h, 3 m wide, 60 channels

Accepted: 0.1 to 10 m
Accepted: 5 to 500 mm
Accepted: 0 to 84.798 °
Accepted: 0.036 to 360,000 m³/h
Accepted: 0.1 to 20 m
Accepted: 1 to 10,000

Results

Laminar flow with uniform velocity between plates. Angles of 55–60° are used so the sludge slides off; keep the channel Reynolds number below about 2,000 and expect real performance below the ideal value because of uneven flow distribution.

Mean fluid velocity between the plates7.7160mm/s
Critical settling to fluid velocity ratio0.092984
Critical settling velocity (smallest fully removed)2.5829m/h
Projected (horizontal) plate area154.87m²
Loading on the projected area2.5829m/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same pack, co-current at 75 deg. The inputs, in the units selected above:

InputValue
Flow patternCo-current (downflow)
Plate length in the flow direction2.0000 m
Perpendicular spacing between plates50.000 mm
Plate angle from horizontal75.000 °
Flow to the plate pack360.00 m³/h
Plate width2.0000 m
Number of plate channels50.000 -

Applying the formula below gives:

ResultValue
Mean fluid velocity between the plates20.000 mm/s
Critical settling to fluid velocity ratio0.10653
Critical settling velocity (smallest fully removed)7.6703 m/h
Projected (horizontal) plate area51.764 m²
Loading on the projected area6.9547 m/h

Open this example in the calculator and change any input.

Formula

\(\frac{v_s}{v_f} = \frac{d}{L_p\cos\theta + d\sin\theta}\ \text{(counter-current)}, \quad \frac{d}{L_p\cos\theta - d\sin\theta}\ \text{(co-current)}, \quad \frac{d}{L_p\cos\theta}\ \text{(cross-flow)}\)

\(v_f = \frac{Q}{nwd}\)

Variables

Symbol Meaning SI unit
\(\text{flow}\) Flow pattern -
\(L_p\) Plate length in the flow direction m
\(d\) Perpendicular spacing between plates m
\(\theta\) Plate angle from horizontal rad
\(Q\) Flow to the plate pack m³/s
\(w\) Plate width m
\(n\) Number of plate channels -
\(v_f\) Mean fluid velocity between the plates m/s
\(v_s/v_f\) Critical settling to fluid velocity ratio -
\(v_s\) Critical settling velocity (smallest fully removed) m/s
\(A_p\) Projected (horizontal) plate area m²
\(Q/A_p\) Loading on the projected area m/s

Method and standards

Ideal-settling trajectory analysis between parallel inclined plates.

Where it is used

  • Retrofitting sedimentation basins with plate packs.
  • Comparing plate spacing and angle.

Common mistakes

  • Using the tank footprint as the settling area.
  • Ignoring flow maldistribution between channels.

Assumptions and limits

  • Laminar, uniform flow; discrete particles.

Questions and answers

Which flow pattern is best?

Below about 60° the three are nearly equal; above 60° counter-current removes the slowest-settling particles.

How do plates raise capacity?

Each plate adds settling area: the projected area of all plates, not the tank footprint, sets the critical settling velocity.

What do the defaults represent?

An illustrative case: Same pack, co-current at 75 deg. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 10-7, eqs. 10-36, 10-40 and 10-42 and Example 10-7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.