Ozone Dose, Transfer Efficiency and Off-Gas Concentration

Applied and transferred ozone dose from feed-gas flow and concentration, the off-gas ozone concentration and the destruct efficiency needed for a vent limit.

Inputs

Examples: Illustrative: 60 Nm3/h at 10 % ozone, 0.5 m3/s water, 95 % transfer, 0.1 ppmv limitAir-fed small plant: 1.5 % ozone, 88 % transfer

Accepted: 0.036 to 36,000 Nm³/h
Accepted: 0.1 to 20 %
Accepted: 0.36 to 180,000 m³/h
Accepted: 50 to 99.99 %
Accepted: 0.01 to 10

Results

Normal conditions 0 °C and 101.325 kPa. The off-gas concentration allows for the gas volume lost with the transferred ozone. Ambient limits are about 0.1 ppmv (OSHA 8-hour), so off-gas always needs thermal or catalytic destruct.

Ozone generated12.849kg/h
Applied ozone dose7.1381mg/L
Transferred ozone dose6.7812mg/L
Off-gas ozone, ppmv5,524.9
Off-gas ozone, mass per normal volume11.831g/m³
Destruct efficiency for the vent limit99.998%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 60 Nm3/h at 10 % ozone, 0.5 m3/s water, 95 % transfer, 0.1 ppmv limit. The inputs, in the units selected above:

InputValue
Feed gas flow (normal)60.000 Nm³/h
Ozone in the feed gas, by volume10.000 %
Water flow1,800.0 m³/h
Transfer efficiency95.000 %
Vent limit for ozone, ppmv0.10000 -

Applying the formula below gives:

ResultValue
Ozone generated12.849 kg/h
Applied ozone dose7.1381 mg/L
Transferred ozone dose6.7812 mg/L
Off-gas ozone, ppmv5,524.9
Off-gas ozone, mass per normal volume11.831 g/m³
Destruct efficiency for the vent limit99.998 %

Open this example in the calculator and change any input.

Formula

\(\dot m_{O_3} = \frac{Q_g\,y_{O_3}}{V_m}M_{O_3}, \quad D_{applied} = \frac{\dot m_{O_3}}{Q_w}, \quad D_{transferred} = TE\cdot D_{applied}\)

\(C_{off} = \frac{y_{O_3}(1 - TE)}{1 - y_{O_3}TE}, \quad \eta_{destruct} = 1 - \frac{C_{vent}}{C_{off}}\)

Variables

Symbol Meaning SI unit
\(Q_g\) Feed gas flow (normal) Nm³/s
\(y_{O_3}\) Ozone in the feed gas, by volume -
\(Q_w\) Water flow m³/s
\(TE\) Transfer efficiency -
\(C_{vent}\) Vent limit for ozone, ppmv -
\(\dot m_{O_3}\) Ozone generated kg/s
\(D_{applied}\) Applied ozone dose kg/m³
\(D_{transferred}\) Transferred ozone dose kg/m³
\(C_{off}\) Off-gas ozone, ppmv -
\(\eta_{destruct}\) Destruct efficiency for the vent limit -

Method and standards

Gas-phase mass balance on an ozone contactor.

Where it is used

  • Ozone dose and generator sizing.
  • Off-gas destruct specification.

Common mistakes

  • Confusing weight and volume per cent of ozone.
  • Taking applied dose as transferred dose.

Assumptions and limits

  • Steady state; normal gas volumes.

References

  • Ozone mass balance between feed gas
  • water and off-gas

Questions and answers

Why destroy the off-gas?

Even at 99.5 % transfer, a feed of several per cent ozone leaves hundreds of ppmv in the off-gas, three to four orders above occupational limits.

What transfer efficiency is typical?

Fine-bubble diffuser contactors reach 85–95 %; side-stream injection with degassing can exceed 95 %.

What do the defaults represent?

An illustrative oxygen-fed plant: 60 Nm³/h of gas at 10 % ozone by volume into 0.5 m³/s of water with 95 % transfer and a 0.1 ppmv vent limit.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 13-7, Example 13-9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.