Membrane Resistance and Fouling Resistance from Flux

Clean membrane resistance coefficient from the clean-water flux, and the total and fouling resistances from a later flux, using the resistance-in-series model.

Inputs

Examples: UF 300 LMH clean at 1 bar; 60 LMH at 1.2 bar, 10 CAfter cleaning 700 LMH at 0.8 bar; 120 LMH at 0.5 bar

Accepted: 0.36 to 36,000 L/(m²·h)
Accepted: 0.01 to 100 bar
Accepted: 0.2 to 2 mPa·s
Accepted: 0.36 to 36,000 L/(m²·h)
Accepted: 0.01 to 100 bar
Accepted: 0.2 to 2 mPa·s

Results

J = ΔP/(μκ): resistances in series, κ_T = κ_m + κ_f (cake, pore blocking, adsorption).

Membrane resistance coefficient1.2000e+121/m
Total resistance in operation5.5088e+121/m
Fouling resistance4.3088e+121/m
Share of resistance from fouling78.217%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: UF 300 LMH clean at 1 bar; 60 LMH at 1.2 bar, 10 C. The inputs, in the units selected above:

InputValue
Clean-water flux300.00 L/(m²·h)
Transmembrane pressure for the clean test1.0000 bar
Water viscosity at the test temperature1.0000 mPa·s
Flux in operation60.000 L/(m²·h)
Transmembrane pressure in operation1.2000 bar
Water viscosity in operation1.3070 mPa·s

Applying the formula below gives:

ResultValue
Membrane resistance coefficient1.2000e+12 1/m
Total resistance in operation5.5088e+12 1/m
Fouling resistance4.3088e+12 1/m
Share of resistance from fouling78.217 %

Open this example in the calculator and change any input.

Formula

\(J = \frac{\Delta P}{\mu\kappa}, \quad \kappa_m = \frac{\Delta P_0}{\mu J_0}, \quad \kappa_f = \kappa_T - \kappa_m\)

Variables

Symbol Meaning SI unit
\(J_0\) Clean-water flux m/s
\(\Delta P_0\) Transmembrane pressure for the clean test Pa
\(\mu\) Water viscosity at the test temperature Pa·s
\(J\) Flux in operation m/s
\(\Delta P\) Transmembrane pressure in operation Pa
\(\mu_2\) Water viscosity in operation Pa·s
\(\kappa_m\) Membrane resistance coefficient 1/m
\(\kappa_T\) Total resistance in operation 1/m
\(\kappa_f\) Fouling resistance 1/m
\(\kappa_f/\kappa_T\) Share of resistance from fouling -

Method and standards

Resistance-in-series model of membrane filtration.

Where it is used

  • Tracking fouling and cleaning recovery.
  • Comparing membranes from clean-water tests.

Common mistakes

  • Mixing L/(m²·h) and m/s.
  • Comparing resistances measured at different temperatures without viscosity.

Assumptions and limits

  • Pressure-driven flow through porous membranes; no osmotic effect.

Questions and answers

Why include viscosity?

Flux through the pores follows Darcy's law, so the same membrane passes more warm water; resistance strips out the temperature effect.

What is a typical clean resistance?

Microfiltration about 10¹¹ m⁻¹, ultrafiltration about 10¹² m⁻¹; fouled membranes several times more.

What do the defaults represent?

An illustrative case: UF 300 LMH clean at 1 bar; 60 LMH at 1.2 bar, 10 C. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 12-5, eq. 12-6 and Examples 12-3 and 12-5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.