Worked example
Example: UF 300 LMH clean at 1 bar; 60 LMH at 1.2 bar, 10 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Clean-water flux | 300.00 L/(m²·h) |
| Transmembrane pressure for the clean test | 1.0000 bar |
| Water viscosity at the test temperature | 1.0000 mPa·s |
| Flux in operation | 60.000 L/(m²·h) |
| Transmembrane pressure in operation | 1.2000 bar |
| Water viscosity in operation | 1.3070 mPa·s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Membrane resistance coefficient | 1.2000e+12 1/m |
| Total resistance in operation | 5.5088e+12 1/m |
| Fouling resistance | 4.3088e+12 1/m |
| Share of resistance from fouling | 78.217 % |
Open this example in the calculator and change any input.
Formula
\(J = \frac{\Delta P}{\mu\kappa}, \quad \kappa_m = \frac{\Delta P_0}{\mu J_0}, \quad \kappa_f = \kappa_T - \kappa_m\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(J_0\) | Clean-water flux | m/s |
| \(\Delta P_0\) | Transmembrane pressure for the clean test | Pa |
| \(\mu\) | Water viscosity at the test temperature | Pa·s |
| \(J\) | Flux in operation | m/s |
| \(\Delta P\) | Transmembrane pressure in operation | Pa |
| \(\mu_2\) | Water viscosity in operation | Pa·s |
| \(\kappa_m\) | Membrane resistance coefficient | 1/m |
| \(\kappa_T\) | Total resistance in operation | 1/m |
| \(\kappa_f\) | Fouling resistance | 1/m |
| \(\kappa_f/\kappa_T\) | Share of resistance from fouling | - |
Method and standards
Resistance-in-series model of membrane filtration.
Where it is used
- Tracking fouling and cleaning recovery.
- Comparing membranes from clean-water tests.
Common mistakes
- Mixing L/(m²·h) and m/s.
- Comparing resistances measured at different temperatures without viscosity.
Assumptions and limits
- Pressure-driven flow through porous membranes; no osmotic effect.
Questions and answers
Why include viscosity?
Flux through the pores follows Darcy's law, so the same membrane passes more warm water; resistance strips out the temperature effect.
What is a typical clean resistance?
Microfiltration about 10¹¹ m⁻¹, ultrafiltration about 10¹² m⁻¹; fouled membranes several times more.
What do the defaults represent?
An illustrative case: UF 300 LMH clean at 1 bar; 60 LMH at 1.2 bar, 10 C. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 12-5, eq. 12-6 and Examples 12-3 and 12-5