FireCADCalc

Hollow-Fibre Membrane Module: Area and Flow, Inside-Out or Outside-In

Membrane area of a hollow-fibre module on the outside or inside fibre surface, the permeate flow at a given flux and the packing density.

Inputs

Examples: Large UF module: 10,000 fibres, 2.0 m, 1.3/0.8 mm, 60 L/(m2 h), 250 mmSubmerged MF cassette element without module diameter

Accepted: 1 to 1,000,000
Accepted: 0.05 to 5 m
Accepted: 0.1 to 5 mm
Accepted: 0.05 to 4 mm
Accepted: 0.36 to 3,600 L/(m²·h)
Accepted: 0 to 1,000 mm

Results

Flux is quoted on the surface that faces the feed: the outside for outside-in (submerged or pressurised) and the inside for inside-out operation, so modules must be compared on flow, not flux.

Membrane area on the outside surface33.929m²
Membrane area on the inside surface15.268m²
Permeate flow, outside-in1,017.9L/h
Permeate flow, inside-out458.04L/h
Flow ratio at equal flux2.2222
Packing density on the outside area0m²/m³
Fibre fill fraction of the module cross-section0%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Large UF module: 10,000 fibres, 2.0 m, 1.3/0.8 mm, 60 L/(m2 h), 250 mm. The inputs, in the units selected above:

InputValue
Number of fibres10,000 -
Fibre length2.0000 m
Fibre outside diameter1.3000 mm
Fibre inside diameter0.80000 mm
Flux60.000 L/(m²·h)
Module inside diameter (0 if unknown)250.00 mm

Applying the formula below gives:

ResultValue
Membrane area on the outside surface81.681 m²
Membrane area on the inside surface50.265 m²
Permeate flow, outside-in4,900.9 L/h
Permeate flow, inside-out3,015.9 L/h
Flow ratio at equal flux1.6250
Packing density on the outside area832.00 m²/m³
Fibre fill fraction of the module cross-section27.040 %

Open this example in the calculator and change any input.

Formula

\(A_{out} = n\pi d_oL, \quad A_{in} = n\pi d_iL, \quad Q = JA\)

\(\frac{A_{out}}{V} = \frac{4n d_o}{D_m^2}, \quad \phi = n\left(\frac{d_o}{D_m}\right)^2\)

Variables

Symbol Meaning SI unit
\(n\) Number of fibres -
\(L\) Fibre length m
\(d_o\) Fibre outside diameter m
\(d_i\) Fibre inside diameter m
\(J\) Flux m/s
\(D_m\) Module inside diameter (0 if unknown) m
\(A_{out}\) Membrane area on the outside surface m²
\(A_{in}\) Membrane area on the inside surface m²
\(Q_{out-in}\) Permeate flow, outside-in m³/s
\(Q_{in-out}\) Permeate flow, inside-out m³/s
\(Q_{out}/Q_{in}\) Flow ratio at equal flux -
\(A_{out}/V\) Packing density on the outside area m²/m³
\(\phi\) Fibre fill fraction of the module cross-section -

Method and standards

Membrane area of a hollow-fibre bundle on either fibre surface.

Where it is used

  • Comparing membrane suppliers' modules.
  • Sizing a membrane plant by module count.

Common mistakes

  • Comparing fluxes quoted on different surfaces.
  • Ignoring potting length that is not active membrane.

Assumptions and limits

  • Active length equals the fibre length entered.

Questions and answers

Why does outside-in give more water at the same flux?

The outside surface is larger by d_o/d_i, so a module rated outside-in has more area.

What is a typical packing density?

Hollow-fibre modules reach several hundred to over 1,000 m² of membrane per m³ of module volume.

What do the defaults represent?

An illustrative case: Large UF module: 10,000 fibres, 2.0 m, 1.3/0.8 mm, 60 L/(m2 h), 250 mm. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 12-3, Example 12-1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.