Worked example
Example: Large UF module: 10,000 fibres, 2.0 m, 1.3/0.8 mm, 60 L/(m2 h), 250 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of fibres | 10,000 - |
| Fibre length | 2.0000 m |
| Fibre outside diameter | 1.3000 mm |
| Fibre inside diameter | 0.80000 mm |
| Flux | 60.000 L/(m²·h) |
| Module inside diameter (0 if unknown) | 250.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Membrane area on the outside surface | 81.681 m² |
| Membrane area on the inside surface | 50.265 m² |
| Permeate flow, outside-in | 4,900.9 L/h |
| Permeate flow, inside-out | 3,015.9 L/h |
| Flow ratio at equal flux | 1.6250 |
| Packing density on the outside area | 832.00 m²/m³ |
| Fibre fill fraction of the module cross-section | 27.040 % |
Open this example in the calculator and change any input.
Formula
\(A_{out} = n\pi d_oL, \quad A_{in} = n\pi d_iL, \quad Q = JA\)
\(\frac{A_{out}}{V} = \frac{4n d_o}{D_m^2}, \quad \phi = n\left(\frac{d_o}{D_m}\right)^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of fibres | - |
| \(L\) | Fibre length | m |
| \(d_o\) | Fibre outside diameter | m |
| \(d_i\) | Fibre inside diameter | m |
| \(J\) | Flux | m/s |
| \(D_m\) | Module inside diameter (0 if unknown) | m |
| \(A_{out}\) | Membrane area on the outside surface | m² |
| \(A_{in}\) | Membrane area on the inside surface | m² |
| \(Q_{out-in}\) | Permeate flow, outside-in | m³/s |
| \(Q_{in-out}\) | Permeate flow, inside-out | m³/s |
| \(Q_{out}/Q_{in}\) | Flow ratio at equal flux | - |
| \(A_{out}/V\) | Packing density on the outside area | m²/m³ |
| \(\phi\) | Fibre fill fraction of the module cross-section | - |
Method and standards
Membrane area of a hollow-fibre bundle on either fibre surface.
Where it is used
- Comparing membrane suppliers' modules.
- Sizing a membrane plant by module count.
Common mistakes
- Comparing fluxes quoted on different surfaces.
- Ignoring potting length that is not active membrane.
Assumptions and limits
- Active length equals the fibre length entered.
Questions and answers
Why does outside-in give more water at the same flux?
The outside surface is larger by d_o/d_i, so a module rated outside-in has more area.
What is a typical packing density?
Hollow-fibre modules reach several hundred to over 1,000 m² of membrane per m³ of module volume.
What do the defaults represent?
An illustrative case: Large UF module: 10,000 fibres, 2.0 m, 1.3/0.8 mm, 60 L/(m2 h), 250 mm. Replace the inputs with your own data.