FireCADCalc

Orthokinetic (Macroscale) Flocculation Time for Particle Reduction

Floc volume fraction, first-order orthokinetic flocculation rate constant and the time to reduce the particle count by a chosen fraction at a given G.

Inputs

Examples: Turbid water 5 um, 1e6/mL, G 40, alpha 0.5, 90 % reductionDilute 20 um, 500/mL, G 80, alpha 0.3, 50 %

Accepted: 0.1 to 1,000 µm
Accepted: 1 to 1E+9
Accepted: 1 to 500 1/s
Accepted: 1 to 100 %
Accepted: 0.1 to 99.9 %

Results

Smoluchowski orthokinetic flocculation of equal spheres with a constant floc volume fraction, giving first-order kinetics; real flocs are fractal and break up, so use for comparisons and trends.

Floc volume fraction2.0944e-06
First-order rate constant0.0038401/min
Time required180.51min
Gt required866,434

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Turbid water 5 um, 1e6/mL, G 40, alpha 0.5, 90 % reduction. The inputs, in the units selected above:

InputValue
Particle diameter5.0000 µm
Initial particle count per mL1,000,000 -
Velocity gradient40.000 1/s
Collision efficiency50.000 %
Fraction of particles to remain10.000 %

Applying the formula below gives:

ResultValue
Floc volume fraction6.5450e-05
First-order rate constant0.10000 1/min
Time required23.026 min
Gt required55,262

Open this example in the calculator and change any input.

Formula

\(\Phi = \frac{\pi d^3n_0}{6}, \quad k = \frac{4\alpha\Phi G}{\pi}, \quad t = \frac{-\ln(n/n_0)}{k}\)

Variables

Symbol Meaning SI unit
\(d\) Particle diameter m
\(n_0\) Initial particle count per mL -
\(G\) Velocity gradient 1/s
\(\alpha\) Collision efficiency -
\(n/n_0\) Fraction of particles to remain -
\(\Phi\) Floc volume fraction -
\(k\) First-order rate constant 1/s
\(t\) Time required s
\(Gt\) Gt required -

Method and standards

Smoluchowski orthokinetic rate written as first-order kinetics.

Where it is used

  • Explaining why dilute waters flocculate poorly.
  • Comparing G and time combinations.

Common mistakes

  • Entering the count per litre instead of per mL.
  • Applying it to colloids below 1 µm.

Assumptions and limits

  • Monodisperse spheres, laminar shear, no floc breakup.

Questions and answers

Why does a higher particle count flocculate faster?

The rate constant is proportional to the floc volume fraction: more solids mean more collisions per particle, which is why ballasted and sludge-blanket processes work.

What about very small particles?

Below about 1 µm Brownian (perikinetic) flocculation dominates; this calculator covers only shear-induced (orthokinetic) collisions.

What do the defaults represent?

An illustrative case: Turbid water 5 um, 1e6/mL, G 40, alpha 0.5, 90 % reduction. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 9-6, eqs. 9-37 and 9-38 and Example 9-4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.