FireCADCalc

Disinfection with a Lag (Rennecker–Mariñas): Log Inactivation and Ct

Log inactivation of oocysts or spores with a lag Ct before inactivation starts (Rennecker–Mariñas model), and the Ct needed for a target log removal.

Inputs

Examples: Within the lag: 0.48 mg/L for 61.6 minOzone on Cryptosporidium at 20 C: L 0.6, b 2.0, 0.5 mg/L for 10 min, 3 log

Accepted: 1E-5 to 100
Accepted: 0 to 10,000
Accepted: 0.01 to 50 mg/L
Accepted: 0.016667 to 16,667 min
Accepted: 0.1 to 8

Results

ln(N/N₀) = 0 for Ct < b and −Λ_CW(Ct − b) beyond it; b and Λ_CW come from fitting bench data (concentration in mg/L, time in min). Constant concentration is assumed; for decaying residuals integrate C over time.

Ct provided, mg·min/L29.568
Log inactivation achieved0
Ct needed for the target, mg·min/L62.642
Contact time needed at C130.50min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Within the lag: 0.48 mg/L for 61.6 min. The inputs, in the units selected above:

InputValue
Coefficient of specific lethality, L/(mg·min)0.083000 -
Lag coefficient, mg·min/L34.900 -
Disinfectant concentration0.48000 mg/L
Contact time61.600 min
Target log inactivation1.0000 -

Applying the formula below gives:

ResultValue
Ct provided, mg·min/L29.568
Log inactivation achieved0
Ct needed for the target, mg·min/L62.642
Contact time needed at C130.50 min

Open this example in the calculator and change any input.

Formula

\(\ln\frac{N}{N_0} = \begin{cases}0 & Ct < b\\ -\Lambda_{CW}(Ct - b) & Ct \ge b\end{cases}\)

\(Ct_{req} = b + \frac{2.303\,\log_{10}(N_0/N)}{\Lambda_{CW}}\)

Variables

Symbol Meaning SI unit
\(\Lambda_{CW}\) Coefficient of specific lethality, L/(mg·min) -
\(b\) Lag coefficient, mg·min/L -
\(C\) Disinfectant concentration kg/m³
\(t\) Contact time s
\(\log_{10}(N_0/N)\) Target log inactivation -
\(Ct\) Ct provided, mg·min/L -
\(Ct_{req}\) Ct needed for the target, mg·min/L -
\(t_{req}\) Contact time needed at C s

Method and standards

Chick–Watson inactivation delayed by a lag Ct.

Where it is used

  • Cryptosporidium and Giardia credit with ClO₂ and ozone.
  • Spore and oocyst inactivation studies.

Common mistakes

  • Applying a first-order Chick–Watson fit to lagging data.
  • Forgetting temperature: Λ and b change with it.

Assumptions and limits

  • Constant C and temperature; parameters from bench tests.

Questions and answers

Why is there a lag?

Resistant organisms such as Cryptosporidium oocysts and spores need several hits before they die, so nothing happens until a threshold Ct is passed.

How do I get Λ and b?

Fit log survival against Ct: the line's intercept on the Ct axis is b and its slope (×2.303) is Λ_CW.

What do the defaults represent?

An illustrative case: Within the lag: 0.48 mg/L for 61.6 min. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 13-3, eqs. 13-5 and 13-6 and Example 13-2 (Rennecker et al. 1997; Corona-Vasquez et al. 2002)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.