FireCADCalc

Electrical Double Layer Thickness (Debye Length)

Ionic strength and the Debye length (thickness of the electrical double layer) around particles for a symmetric electrolyte at a given concentration and temperature.

Inputs

Examples: Seawater-strength 0.5 M NaCl

Accepted: 1E-7 to 1
Accepted: 1 to 4
Accepted: 0 to 100 °C
Accepted: 50 to 90

Results

The double layer shrinks as ionic strength rises; compressing it lets particles approach and flocculate (the mechanism of double-layer compression in coagulation).

Ionic strength, mol/L0.50000
Debye length0.43032nm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Seawater-strength 0.5 M NaCl. The inputs, in the units selected above:

InputValue
Electrolyte molarity, mol/L0.50000 -
Ion charge (symmetric electrolyte)1.0000 -
Temperature25.000 °C
Relative permittivity of water78.540 -

Applying the formula below gives:

ResultValue
Ionic strength, mol/L0.50000
Debye length0.43032 nm

Open this example in the calculator and change any input.

Formula

\(\frac{1}{\kappa} = \left(\frac{\varepsilon_r\varepsilon_0kT}{2\times1000\,e^2N_AI}\right)^{1/2}, \quad I = \frac12\sum M_iz_i^2\)

Variables

Symbol Meaning SI unit
\(M\) Electrolyte molarity, mol/L -
\(z\) Ion charge (symmetric electrolyte) -
\(T\) Temperature K
\(\varepsilon_r\) Relative permittivity of water -
\(I\) Ionic strength, mol/L -
\(1/\kappa\) Debye length m

Method and standards

Gouy–Chapman double-layer thickness.

Where it is used

  • Explaining coagulation by double-layer compression.
  • Colloid stability screening.

Common mistakes

  • Forgetting the factor 1,000 L/m³.
  • Using molarity instead of ionic strength.

Assumptions and limits

  • Symmetric electrolyte; dilute solution.

Questions and answers

Why are seawater colloids unstable?

At seawater ionic strength the double layer is under a nanometre thick, so particles approach close enough for van der Waals attraction to win.

How does charge matter?

Divalent ions raise ionic strength four times as much as monovalent ones at the same molarity, halving the Debye length.

What do the defaults represent?

An illustrative case: Seawater-strength 0.5 M NaCl. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 9-2, eq. 9-4 and Example 9-1; CODATA 2018 constants

Related calculators