Chlorine Residual Decay and Temperature (Arrhenius)

First-order chlorine residual decay constant at another temperature by the Arrhenius equation, residual after a storage time at both temperatures and half-lives.

Inputs

Examples: Reservoir 1.5 mg/L, 0.02 1/h at 20 C, Ea 70 kJ/mol, summer 30 C, 48 hCold main 0.8 mg/L, 0.05 1/h at 20 C to 8 C, 24 h

Accepted: 0.001 to 50 mg/L
Accepted: 3.6E-5 to 3,600 1/h
Accepted: 0 to 50 °C
Accepted: 1 to 200 kJ/mol
Accepted: 0 to 50 °C
Accepted: 0.016667 to 2,777.8 h

Results

Bulk-water first-order decay; pipe-wall demand adds to it in distribution systems. Fit k_d from a bottle test as the slope of ln(C/C₀) against time.

Decay constant at the other temperature0.0168831/h
Residual after the time at T₁0.24096mg/L
Residual after the time at T₂0.53348mg/L
Half-life at T₁13.863h
Half-life at T₂41.055h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Reservoir 1.5 mg/L, 0.02 1/h at 20 C, Ea 70 kJ/mol, summer 30 C, 48 h. The inputs, in the units selected above:

InputValue
Initial residual1.5000 mg/L
Decay constant at the test temperature0.020000 1/h
Test temperature20.000 °C
Activation energy70.000 kJ/mol
Other temperature30.000 °C
Storage or travel time48.000 h

Applying the formula below gives:

ResultValue
Decay constant at the other temperature0.051578 1/h
Residual after the time at T₁0.57434 mg/L
Residual after the time at T₂0.12615 mg/L
Half-life at T₁34.657 h
Half-life at T₂13.439 h

Open this example in the calculator and change any input.

Formula

\(C = C_0e^{-k_dt}, \quad k_{d,2} = k_{d,1}\exp\left[\frac{E_a}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)\right], \quad t_{1/2} = \frac{\ln 2}{k_d}\)

Variables

Symbol Meaning SI unit
\(C_0\) Initial residual kg/m³
\(k_{d,1}\) Decay constant at the test temperature 1/s
\(T_1\) Test temperature K
\(E_a\) Activation energy J/mol
\(T_2\) Other temperature K
\(t\) Storage or travel time s
\(k_{d,2}\) Decay constant at the other temperature 1/s
\(C_1(t)\) Residual after the time at T₁ kg/m³
\(C_2(t)\) Residual after the time at T₂ kg/m³
\(t_{1/2,1}\) Half-life at T₁ s
\(t_{1/2,2}\) Half-life at T₂ s

Method and standards

First-order decay with Arrhenius temperature dependence.

Where it is used

  • Booster chlorination planning and storage tank residuals.
  • Seasonal dosing adjustments.

Common mistakes

  • Using °C in the Arrhenius equation.
  • Assuming bulk decay covers wall demand in old mains.

Assumptions and limits

  • First-order bulk decay; constant temperature during the time.

Questions and answers

Why does warm water lose chlorine faster?

The decay reactions follow Arrhenius kinetics; with E_a about 60 kJ/mol the rate nearly quadruples from 10 to 25 °C.

How do I get k_d?

Dose a sample, store it dark at constant temperature and measure the residual; the slope of ln(C/C₀) against time is −k_d.

What do the defaults represent?

An illustrative case: Reservoir 1.5 mg/L, 0.02 1/h at 20 C, Ea 70 kJ/mol, summer 30 C, 48 h. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 13-5, Example 13-5, with the Arrhenius equation 5-85

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.