FireCADCalc

Sluice Gate Discharge (Free Flow)

Discharge under a vertical sluice gate in free flow from the upstream depth and gate opening, by Swamee's discharge coefficient and the energy equation.

Inputs

Examples: Illustrative: 3 m gate opened 0.4 m, 2 m upstream, 0.9 m tailwaterLaboratory flume 0.3 m wide, 0.25 m depth, 0.05 m openingDrowned gate: 1.5 m upstream, 0.5 m opening, 1.2 m tailwater

Accepted: 0.01 to 50 m
Accepted: 0.005 to 20 m
Accepted: 0.05 to 100 m
Accepted: 0 to 50 m
Accepted: 0.5 to 0.75

Results

Free flow: the jet leaves the gate supercritical and the jump forms downstream. Swamee's C_d fits the experimental data for free flow; the energy equation with C_c ≈ 0.61 is the classical check.

Discharge coefficient (Swamee)0.54415
Discharge (Swamee)4.0897m³/s
Discharge from energy with C_c4.3282m³/s
Depth at the vena contracta C_c a0.24400m
Froude number at the vena contracta3.8224
Sequent depth of the jump (free flow needs tailwater below this)1.2026m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 3 m gate opened 0.4 m, 2 m upstream, 0.9 m tailwater. The inputs, in the units selected above:

InputValue
Upstream depth2.0000 m
Gate opening0.40000 m
Gate width3.0000 m
Tailwater depth downstream (0 if unknown)0.90000 m
Contraction coefficient0.61000 -

Applying the formula below gives:

ResultValue
Discharge coefficient (Swamee)0.54415
Discharge (Swamee)4.0897 m³/s
Discharge from energy with C_c4.3282 m³/s
Depth at the vena contracta C_c a0.24400 m
Froude number at the vena contracta3.8224
Sequent depth of the jump (free flow needs tailwater below this)1.2026 m

Open this example in the calculator and change any input.

Formula

\(Q = C_d B a\sqrt{2gy_1}, \quad C_d = 0.611\left(\frac{y_1 - a}{y_1 + 15a}\right)^{0.072}\)

\(Q_E = C_c a B\sqrt{\frac{2gy_1}{1 + C_c a/y_1}}, \quad y_2' = \frac{y_2}{2}\left(\sqrt{1 + 8Fr_2^2} - 1\right)\)

Variables

Symbol Meaning SI unit
\(y_1\) Upstream depth m
\(a\) Gate opening m
\(B\) Gate width m
\(y_3\) Tailwater depth downstream (0 if unknown) m
\(C_c\) Contraction coefficient -
\(C_d\) Discharge coefficient (Swamee) -
\(Q\) Discharge (Swamee) m³/s
\(Q_E\) Discharge from energy with C_c m³/s
\(y_2\) Depth at the vena contracta C_c a m
\(Fr_2\) Froude number at the vena contracta -
\(y_{2}'\) Sequent depth of the jump (free flow needs tailwater below this) m

Method and standards

Free-flow sluice gate discharge.

Where it is used

  • Irrigation canal head regulators and cross regulators.
  • Spillway and barrage gates, flumes in laboratories.

Common mistakes

  • Using the free-flow equation for a drowned gate.
  • Measuring the upstream depth too close to the gate.

Assumptions and limits

  • Vertical sharp-edged gate, free flow, rectangular channel.

References

  • Swamee's free-flow discharge coefficient; energy equation with contraction coefficient; momentum for the sequent depth
  • Swamee
  • Sluice-gate discharge equations
  • J. Irrigation and Drainage Engineering 118(1)
  • 1992

Questions and answers

When is the flow submerged?

When the tailwater is deeper than the sequent depth of the jet's hydraulic jump; the jump then drowns the gate and the discharge falls for the same upstream depth.

What contraction coefficient should I use?

About 0.61 for a sharp-edged vertical gate; radial (Tainter) gates have different values that depend on the lip angle.

What do the defaults represent?

An illustrative 3 m wide canal gate opened 0.4 m with 2 m of water upstream and 0.9 m tailwater.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Henderson, Open Channel Flow (Macmillan, 1966), sec. 6.6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.