FireCADCalc

Sediment Threshold of Motion (Shields) in Channel Flow

Critical Shields parameter, critical bed shear stress and shear velocity for a sediment grain, compared with the bed shear of the flow to judge if the bed moves.

Inputs

Examples: Illustrative: 0.5 mm sand, R 1.2 m, S 0.0002Gravel 20 mm in a steep stream, R 0.8 m, S 0.005Fine silt 0.05 mm, R 2 m, S 0.00005

Accepted: 0.001 to 1,000 mm
Accepted: 1,000 to 8,000 kg/m³
Accepted: 900 to 1,100 kg/m³
Accepted: 0.1 to 100 mm²/s
Accepted: 0.001 to 100 m
Accepted: 1E-7 to 0.5

Results

Soulsby–Whitehouse fit of the Shields curve, for non-cohesive grains on a flat bed in steady flow. Bed forms, armouring, cohesion and bank slopes change the real threshold.

Dimensionless grain size1.0617
Critical Shields parameter0.13308
Critical bed shear stress0.10767Pa
Critical shear velocity0.010376m/s
Bed shear stress ρgR_hS0.98067Pa
Mobility ratio (above 1: the bed moves)9.1083

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 0.5 mm sand, R 1.2 m, S 0.0002. The inputs, in the units selected above:

InputValue
Grain diameter (d₅₀)0.50000 mm
Grain density2,650.0 kg/m³
Water density1,000.0 kg/m³
Kinematic viscosity1.0000 mm²/s
Hydraulic radius (≈ depth for wide channels)1.2000 m
Energy slope2.0000e-04 -

Applying the formula below gives:

ResultValue
Dimensionless grain size12.647
Critical Shields parameter0.030837
Critical bed shear stress0.24949 Pa
Critical shear velocity0.015795 m/s
Bed shear stress ρgR_hS2.3536 Pa
Mobility ratio (above 1: the bed moves)9.4336

Open this example in the calculator and change any input.

Formula

\(D_* = d\left[\frac{(s - 1)g}{\nu^2}\right]^{1/3}, \quad \theta_{cr} = \frac{0.30}{1 + 1.2D_*} + 0.055\left(1 - e^{-0.020D_*}\right)\)

\(\tau_{cr} = \theta_{cr}(\rho_s - \rho)gd, \quad \tau_b = \rho gR_hS\)

Variables

Symbol Meaning SI unit
\(d\) Grain diameter (d₅₀) m
\(\rho_s\) Grain density kg/m³
\(\rho\) Water density kg/m³
\(\nu\) Kinematic viscosity m²/s
\(R_h\) Hydraulic radius (≈ depth for wide channels) m
\(S\) Energy slope -
\(D_*\) Dimensionless grain size -
\(\theta_{cr}\) Critical Shields parameter -
\(\tau_{cr}\) Critical bed shear stress Pa
\(u_{*cr}\) Critical shear velocity m/s
\(\tau_b\) Bed shear stress ρgR_hS Pa
\(\tau_b/\tau_{cr}\) Mobility ratio (above 1: the bed moves) -

Method and standards

Threshold of sediment motion.

Where it is used

  • Stable channel and canal design, scour checks.
  • Riprap and bed protection, sediment transport studies.

Common mistakes

  • Using d₉₀ instead of d₅₀ for a mixed bed without justification.
  • Ignoring bank slope, which lowers the threshold on the banks.

Assumptions and limits

  • Non-cohesive grains, flat bed, steady uniform flow.

References

  • Shields criterion with the Soulsby–Whitehouse formula

Questions and answers

What does the Shields parameter mean?

The ratio of the fluid force on a grain to its submerged weight; motion starts when it reaches a critical value of about 0.03–0.06 for sand and gravel.

Why use D* instead of the grain Reynolds number?

D* depends only on the grain and the fluid, so the threshold can be found directly without iteration.

What do the defaults represent?

An illustrative medium sand bed (0.5 mm) in a channel with a 1.2 m hydraulic radius and a slope of 0.0002.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Soulsby, Dynamics of Marine Sands (Thomas Telford, 1997), sec. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.