FireCADCalc

Septic Tank Volume and Soak Pit Size

Septic tank liquid and sludge volume and plan dimensions for a number of users, and the diameter of a soak pit from the soil infiltration rate.

Inputs

Examples: Illustrative 20 usersClay soil 20 L/m2/dSingle house 5 users, sandy soilCamp 100 users, two-day detention

Accepted: 1 to 10,000
Accepted: 8.64 to 864 L/d
Accepted: 1 to 120 h
Accepted: 5 to 200 L
Accepted: 0.5 to 10
Accepted: 1 to 3 m
Accepted: 1 to 5
Accepted: 0.864 to 86,400 mm/d
Accepted: 0.5 to 6 m

Results

V = N·q·t + N·r_s·n_y; plan from depth and L/W; soak pit wall plus floor area πD·h + πD²/4 = Nq/i. Add freeboard above the liquid; take percolation rates from a test pit, and check groundwater level and distance to wells.

Liquid volume14.000m³
Sludge volume4.0000m³
Tank working volume18.000m³
Tank width1.8257m
Tank length5.4772m
Infiltration area needed466.67m²
Soak pit diameter19.103m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 users. The inputs, in the units selected above:

InputValue
Users20.000 -
Wastewater per user90.000 L/d
Detention time24.000 h
Sludge per user per year30.000 L
Desludging interval (years)2.0000 -
Liquid depth1.5000 m
Length-to-width ratio3.0000 -
Soil infiltration rate50.000 mm/d
Soak pit effective depth3.0000 m

Applying the formula below gives:

ResultValue
Liquid volume1.8000 m³
Sludge volume1.2000 m³
Tank working volume3.0000 m³
Tank width0.81650 m
Tank length2.4495 m
Infiltration area needed36.000 m²
Soak pit diameter3.0464 m

Open this example in the calculator and change any input.

Formula

\(V = Nqt + Nr_sn_y, \quad \pi D_ph_p + \frac{\pi D_p^2}{4} = \frac{Nq}{i}\)

Variables

Symbol Meaning SI unit
\(N\) Users -
\(q\) Wastewater per user m³/s
\(t\) Detention time s
\(r_s\) Sludge per user per year m³
\(n_y\) Desludging interval (years) -
\(h\) Liquid depth m
\(L/W\) Length-to-width ratio -
\(i\) Soil infiltration rate m/s
\(h_p\) Soak pit effective depth m
\(V_l\) Liquid volume m³
\(V_s\) Sludge volume m³
\(V\) Tank working volume m³
\(W\) Tank width m
\(L\) Tank length m
\(A_s\) Infiltration area needed m²
\(D_p\) Soak pit diameter m

Method and standards

Septic sizing.

Where it is used

  • Rural and site sanitation.
  • Construction camp facilities.

Common mistakes

  • Forgetting sludge storage.
  • Sizing soak pits without a percolation test.

Assumptions and limits

  • Domestic wastewater; uniform soil.

References

  • Septic tank detention and sludge storage; soak-away sizing

Questions and answers

How big should a septic tank for 20 people be?

About 3 m³ of working volume with a two-year desludging interval by these defaults, plus freeboard.

Why measure infiltration?

Soil permeability varies a hundredfold between sand and clay; a soak pit sized for sand will flood in clay.

What do the defaults represent?

An illustrative house group of 20 users at 90 L a day each, one-day detention, 30 L of sludge per user a year, desludged every two years, soil taking 50 L/m² a day into a 3 m deep soak pit.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy, Wastewater Engineering (McGraw-Hill)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.