FireCADCalc

Optimum Number of Rain Gauges

Optimum number of rain gauges for a catchment from the coefficient of variation of the rainfall at existing stations and the allowable error in mean rainfall.

Inputs

Examples: Illustrative five stations, 10 % errorSame stations, 5 % errorSix hill stations

Accepted: 0 to 20,000 mm
Accepted: 0 to 20,000 mm
Accepted: 0 to 20,000 mm
Accepted: 0 to 20,000 mm
Accepted: 0 to 20,000 mm
Accepted: 0 to 20,000 mm
Accepted: 1 to 50 %

Results

The number of gauges needed for the mean rainfall to be within an error ε is N = (C_v/ε)², where C_v is the coefficient of variation (sample standard deviation over mean) of the rainfall at the existing stations. An error of 10 % is usual. The World Meteorological Organization also gives minimum densities for flat, hilly and mountainous areas; at least 10 % of gauges should be self-recording.

Mean rainfall822.00mm
Coefficient of variation17.763%
Optimum number of gauges13.000
Additional gauges8.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative five stations, 10 % error. The inputs, in the units selected above:

InputValue
Rainfall, station 1820.00 mm
Rainfall, station 2650.00 mm
Rainfall, station 3720.00 mm
Rainfall, station 4 (0 = none)900.00 mm
Rainfall, station 5 (0 = none)1,020.0 mm
Rainfall, station 6 (0 = none)0 mm
Allowable error in mean rainfall10.000 %

Applying the formula below gives:

ResultValue
Mean rainfall822.00 mm
Coefficient of variation17.763 %
Optimum number of gauges4.0000
Additional gauges0

Open this example in the calculator and change any input.

Formula

\(C_v = \frac{\sigma_{n-1}}{\bar P}, \quad N = \left(\frac{C_v}{\varepsilon}\right)^2\)

Variables

Symbol Meaning SI unit
\(P_1\) Rainfall, station 1 m
\(P_2\) Rainfall, station 2 m
\(P_3\) Rainfall, station 3 m
\(P_4\) Rainfall, station 4 (0 = none) m
\(P_5\) Rainfall, station 5 (0 = none) m
\(P_6\) Rainfall, station 6 (0 = none) m
\(\varepsilon\) Allowable error in mean rainfall -
\(\bar P\) Mean rainfall m
\(C_v\) Coefficient of variation -
\(N\) Optimum number of gauges -
\(N - n\) Additional gauges -

Method and standards

Rain gauge network.

Where it is used

  • Catchment hydrology studies.
  • Civil engineering examinations.

Common mistakes

  • Using the population standard deviation.
  • Ignoring topography in gauge placement.

Assumptions and limits

  • Station rainfall over the same period.

References

  • Classical engineering hydrology relations

Questions and answers

How many gauges for these five stations at 10 % error?

Mean 822 mm, C_v 17.8 %: four gauges, so the five existing ones suffice.

What if 5 % error is wanted?

N rises fourfold, to 13 gauges.

What do the defaults represent?

Five stations recording 820, 650, 720, 900 and 1,020 mm of annual rainfall, allowable error 10 %.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.