φ-Index and W-Index from a Storm Hyetograph

φ-index (constant loss rate giving the observed runoff) and W-index of a storm from six interval rainfall depths and the measured direct runoff depth.

Inputs

Examples: Illustrative six-hour stormTwo-hour intervalsSmall runoff

Accepted: 0.16667 to 24 h
Accepted: 0 to 1,000 mm
Accepted: 0 to 1,000 mm
Accepted: 0 to 1,000 mm
Accepted: 0 to 1,000 mm
Accepted: 0 to 1,000 mm
Accepted: 0 to 1,000 mm
Accepted: 0 to 5,000 mm

Results

The φ-index is the constant loss rate above which all rainfall becomes runoff: the rainfall in each interval in excess of φ·Δt, summed, equals the observed direct runoff. Intervals with less rain than φ·Δt contribute nothing. The W-index spreads the total loss over the whole storm duration and is lower. Both lump infiltration, interception and depression storage; they vary from storm to storm and with antecedent moisture.

Total rainfall41.000mm
φ-index14.000mm/h
W-index (average loss rate)5.8333mm/h
Losses35.000mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative six-hour storm. The inputs, in the units selected above:

InputValue
Interval length1.0000 h
Rainfall, interval 14.0000 mm
Rainfall, interval 29.0000 mm
Rainfall, interval 315.000 mm
Rainfall, interval 412.000 mm
Rainfall, interval 57.0000 mm
Rainfall, interval 63.0000 mm
Direct runoff depth25.000 mm

Applying the formula below gives:

ResultValue
Total rainfall50.000 mm
φ-index4.5000 mm/h
W-index (average loss rate)4.1667 mm/h
Losses25.000 mm

Open this example in the calculator and change any input.

Formula

\(\sum_i \max(0,\ P_i - \phi\,\Delta t) = R, \quad W = \frac{P - R}{t}\)

Variables

Symbol Meaning SI unit
\(\Delta t\) Interval length s
\(P_1\) Rainfall, interval 1 m
\(P_2\) Rainfall, interval 2 m
\(P_3\) Rainfall, interval 3 m
\(P_4\) Rainfall, interval 4 m
\(P_5\) Rainfall, interval 5 m
\(P_6\) Rainfall, interval 6 m
\(R\) Direct runoff depth m
\(P\) Total rainfall m
\(\phi\) φ-index m/s
\(W\) W-index (average loss rate) m/s
\(P - R\) Losses m

Method and standards

φ-index.

Where it is used

  • Flood hydrograph analysis.
  • Civil engineering examinations.

Common mistakes

  • Including base flow in the runoff.
  • Spreading losses into intervals below φ.

Assumptions and limits

  • Constant loss rate through the storm.

References

  • Classical engineering hydrology relations

Questions and answers

What φ-index gives 25 mm of runoff from 4, 9, 15, 12, 7 and 3 mm hourly rain?

4.5 mm/h; the W-index is 4.2 mm/h.

Why is W lower than φ?

W averages the loss over all intervals, including those with little rain.

What do the defaults represent?

An illustrative six-hour storm with 4, 9, 15, 12, 7 and 3 mm in successive hours and 25 mm of direct runoff.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.