Worked example
Example: Illustrative 5 m well, fine sand. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Depression when pumping stops | 3.0000 m |
| Depression after the recovery time | 1.0000 m |
| Recovery time | 2.0000 h |
| Well diameter | 5.0000 m |
| Safe working depression head | 2.5000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific yield (per hour) | 0.54931 1/h |
| Well area | 19.635 m² |
| Safe yield | 26.964 m³/h |
| Safe yield per day | 647.14 m³/d |
Open this example in the calculator and change any input.
Formula
\(\frac KA = \frac{2.303}{T}\log\frac{s_1}{s_2}, \quad Q = \frac KA\,A\,H\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(s_1\) | Depression when pumping stops | m |
| \(s_2\) | Depression after the recovery time | m |
| \(T\) | Recovery time | s |
| \(d\) | Well diameter | m |
| \(H\) | Safe working depression head | m |
| \(K/A\) | Specific yield (per hour) | 1/s |
| \(A\) | Well area | m² |
| \(Q\) | Safe yield | m³/s |
| \(Q_d\) | Safe yield per day | m³/s |
Method and standards
Recuperation test.
Where it is used
- Village and farm open wells.
- Civil engineering examinations.
Common mistakes
- Using a working head above the critical depression.
- Ignoring seasonal water-table change.
Assumptions and limits
- Inflow through the bottom only.
References
- Classical engineering hydrology relations: recuperation test of open wells
Questions and answers
What is the yield of a 5 m well whose depression recovers from 3 m to 1 m in 2 hours?
K/A = 0.549 per hour; at 2.5 m working head, about 27 m³/h.
What K/A is typical for fine sand?
About 0.5 per hour.
What do the defaults represent?
An illustrative 5 m diameter open well recovering from 3 m to 1 m depression in 2 hours, worked at 2.5 m depression.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.