FireCADCalc

Horton Infiltration Capacity and Cumulative Infiltration

Infiltration capacity of soil at a time and the cumulative infiltration by Horton's exponential decay from initial to final rate, with the runoff from steady rain.

Inputs

Examples: Illustrative: f0 75, fc 10 mm/h, k 4/h, rain 30 mm/h, 1 hClay soil: f0 25, fc 1 mm/h, k 2/h, rain 12 mm/h, 3 hCapacity only, no rain: sandy soil after 30 min

Accepted: 0.0036 to 3,600 mm/h
Accepted: 0 to 3,600 mm/h
Accepted: 0.00036 to 3,600 1/h
Accepted: 0 to 2,777.8 h
Accepted: 0 to 3,600 mm/h

Results

Horton capacity curve; F(t) assumes water is always available at the surface. The runoff estimate is simple: rain in excess of the capacity curve after the time it falls to the rain intensity (0 if the rain never exceeds the capacity).

Infiltration capacity at t11.191mm/h
Cumulative infiltration to t25.952mm
Rainfall excess to t (rain always at or above capacity after ponding)9.4044mm
Time for capacity to fall to the rain intensity0.29466h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: f0 75, fc 10 mm/h, k 4/h, rain 30 mm/h, 1 h. The inputs, in the units selected above:

InputValue
Initial infiltration capacity75.000 mm/h
Final (steady) infiltration capacity10.000 mm/h
Decay constant4.0000 1/h
Time since the start of rain1.0000 h
Rainfall intensity (0 to skip runoff)30.000 mm/h

Applying the formula below gives:

ResultValue
Infiltration capacity at t11.191 mm/h
Cumulative infiltration to t25.952 mm
Rainfall excess to t (rain always at or above capacity after ponding)9.4044 mm
Time for capacity to fall to the rain intensity0.29466 h

Open this example in the calculator and change any input.

Formula

\(f(t) = f_c + (f_0 - f_c)e^{-kt}, \quad F(t) = f_c t + \frac{f_0 - f_c}{k}\left(1 - e^{-kt}\right)\)

Variables

Symbol Meaning SI unit
\(f_0\) Initial infiltration capacity m/s
\(f_c\) Final (steady) infiltration capacity m/s
\(k\) Decay constant 1/s
\(t\) Time since the start of rain s
\(i\) Rainfall intensity (0 to skip runoff) m/s
\(f(t)\) Infiltration capacity at t m/s
\(F(t)\) Cumulative infiltration to t m
\(R\) Rainfall excess to t (rain always at or above capacity after ponding) m
\(t_c\) Time for capacity to fall to the rain intensity s

Method and standards

Empirical exponential infiltration decay.

Where it is used

  • Urban drainage and runoff modelling.
  • Irrigation scheduling and soil assessment.

Common mistakes

  • Using hourly k with times in minutes.
  • Applying the capacity curve when the rain is lighter than the capacity.

Assumptions and limits

  • Water ponded at the surface; homogeneous soil.

References

  • Horton's infiltration equation

Questions and answers

Where do f₀, f_c and k come from?

From infiltrometer tests fitted to the curve; typical sandy loam values are f₀ ≈ 70–250 mm/h, f_c ≈ 10–25 mm/h and k ≈ 2–5 per hour.

Is Horton better than the SCS curve number?

Horton describes the rate over time for a site with test data; the curve number is for event runoff volumes over a catchment.

What do the defaults represent?

An illustrative soil with f₀ = 75 mm/h, f_c = 10 mm/h and k = 4 per hour under 30 mm/h of rain, after one hour.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), sec. 4.3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.