Worked example
Example: Illustrative 50 L/s, 2 % cross slope. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gutter flow | 50.000 L/s |
| Manning's n of the gutter and pavement | 0.016000 - |
| Pavement cross slope | 2.0000 % |
| Longitudinal slope | 1.0000 % |
| Allowable spread (0 = skip check) | 3.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Spread of flow from the kerb | 2.7216 m |
| Depth at the kerb | 54.431 mm |
| Mean velocity | 0.67504 m/s |
| Flow at the allowable spread | 64.830 L/s |
Open this example in the calculator and change any input.
Formula
\(Q = \frac{K_u}{n} S_x^{5/3} S_L^{1/2} T^{8/3}, \quad K_u = 0.376, \quad d = T S_x\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Gutter flow | m³/s |
| \(n\) | Manning's n of the gutter and pavement | - |
| \(S_x\) | Pavement cross slope | - |
| \(S_L\) | Longitudinal slope | - |
| \(T_{allow}\) | Allowable spread (0 = skip check) | m |
| \(T\) | Spread of flow from the kerb | m |
| \(d\) | Depth at the kerb | m |
| \(V\) | Mean velocity | m/s |
| \(Q_{allow}\) | Flow at the allowable spread | m³/s |
Method and standards
Gutter flow.
Where it is used
- Road and car park drainage.
- Spacing of kerb and grate inlets.
Common mistakes
- Using percentages for slopes.
- Applying it to composite gutters without splitting them.
Assumptions and limits
- Uniform triangular section; steady flow.
References
- Modified Manning (Izzard) equation for triangular gutters
Questions and answers
How wide does a gutter flow spread?
T = (Q n /(0.376 S_x^(5/3) S_L^(1/2)))^(3/8) in SI units: 50 L/s on 2 % cross slope and 1 % grade spreads about 2.7 m.
Why does a small flow spread so wide?
On a flat cross slope the water is shallow, so it needs a wide section to carry the flow.
What do the defaults represent?
An illustrative 50 L/s in a concrete gutter (n = 0.016) on 2 % cross slope and 1 % grade, against a 3 m allowable spread.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
FHWA Hydraulic Engineering Circular No. 22, Urban Drainage Design Manual, 3rd ed. (2013)