FireCADCalc

Road Gutter Flow Spread (Izzard Equation)

Width of flow spread and depth at the kerb of stormwater in a triangular road gutter from the flow, cross slope and longitudinal slope.

Inputs

Examples: Illustrative 50 L/s, 2 % cross slopeSteep streetFlat car park

Accepted: 0.1 to 5,000 L/s
Accepted: 0.01 to 0.03
Accepted: 0.5 to 15 %
Accepted: 0.05 to 15 %
Accepted: 0 to 10 m

Results

Manning's equation integrated across a triangular section gives Q = (K_u/n) S_x^(5/3) S_L^(1/2) T^(8/3) with K_u = 0.376 in SI units, so the spread grows only with Q^(3/8). Drainage design limits the spread so that a traffic lane stays open; inlets are placed where the gutter flow reaches the allowable spread. Flatter cross slopes spread water much wider.

Spread of flow from the kerb2.7216m
Depth at the kerb54.431mm
Mean velocity0.67504m/s
Flow at the allowable spread64.830L/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50 L/s, 2 % cross slope. The inputs, in the units selected above:

InputValue
Gutter flow50.000 L/s
Manning's n of the gutter and pavement0.016000 -
Pavement cross slope2.0000 %
Longitudinal slope1.0000 %
Allowable spread (0 = skip check)3.0000 m

Applying the formula below gives:

ResultValue
Spread of flow from the kerb2.7216 m
Depth at the kerb54.431 mm
Mean velocity0.67504 m/s
Flow at the allowable spread64.830 L/s

Open this example in the calculator and change any input.

Formula

\(Q = \frac{K_u}{n} S_x^{5/3} S_L^{1/2} T^{8/3}, \quad K_u = 0.376, \quad d = T S_x\)

Variables

Symbol Meaning SI unit
\(Q\) Gutter flow m³/s
\(n\) Manning's n of the gutter and pavement -
\(S_x\) Pavement cross slope -
\(S_L\) Longitudinal slope -
\(T_{allow}\) Allowable spread (0 = skip check) m
\(T\) Spread of flow from the kerb m
\(d\) Depth at the kerb m
\(V\) Mean velocity m/s
\(Q_{allow}\) Flow at the allowable spread m³/s

Method and standards

Gutter flow.

Where it is used

  • Road and car park drainage.
  • Spacing of kerb and grate inlets.

Common mistakes

  • Using percentages for slopes.
  • Applying it to composite gutters without splitting them.

Assumptions and limits

  • Uniform triangular section; steady flow.

References

  • Modified Manning (Izzard) equation for triangular gutters

Questions and answers

How wide does a gutter flow spread?

T = (Q n /(0.376 S_x^(5/3) S_L^(1/2)))^(3/8) in SI units: 50 L/s on 2 % cross slope and 1 % grade spreads about 2.7 m.

Why does a small flow spread so wide?

On a flat cross slope the water is shallow, so it needs a wide section to carry the flow.

What do the defaults represent?

An illustrative 50 L/s in a concrete gutter (n = 0.016) on 2 % cross slope and 1 % grade, against a 3 m allowable spread.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

FHWA Hydraulic Engineering Circular No. 22, Urban Drainage Design Manual, 3rd ed. (2013)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.