FireCADCalc

Peak Flood by Dickens, Ryves and Inglis Formulas

Maximum flood discharge of a catchment from its area by the Dickens, Ryves and Inglis empirical formulas used in Indian practice.

Inputs

Examples: Illustrative 500 km2 catchmentSmall hilly catchmentLarge plain catchment

Accepted: 0.01 to 1,000,000 km²
Accepted: 1 to 40
Accepted: 1 to 20

Results

These regional formulas give peak flood (m³/s) from catchment area (km²) alone: Dickens Q = C_D·A^¾ for north and central India (C_D about 6 to 30, 11–14 typical), Ryves Q = C_R·A^⅔ for south India (C_R 6.8 near the coast, 8.5 inland, 10.2 for hilly areas) and Inglis Q = 124A/√(A + 10.4) for fan-shaped catchments in Maharashtra. They ignore rainfall intensity and return period, so use them only for preliminary estimates or checks of unit-hydrograph or frequency studies.

Dickens1,205.4m³/s
Ryves428.37m³/s
Inglis (fan-shaped catchments)2,744.3m³/s
Dickens flood per km²2.4108m³/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 500 km2 catchment. The inputs, in the units selected above:

InputValue
Catchment area500.00 km²
Dickens constant11.400 -
Ryves constant6.8000 -

Applying the formula below gives:

ResultValue
Dickens1,205.4 m³/s
Ryves428.37 m³/s
Inglis (fan-shaped catchments)2,744.3 m³/s
Dickens flood per km²2.4108 m³/s

Open this example in the calculator and change any input.

Formula

\(Q_D = C_DA^{3/4}, \quad Q_R = C_RA^{2/3}, \quad Q_I = \frac{124A}{\sqrt{A + 10.4}}\)

Variables

Symbol Meaning SI unit
\(A\) Catchment area m²
\(C_D\) Dickens constant -
\(C_R\) Ryves constant -
\(Q_D\) Dickens m³/s
\(Q_R\) Ryves m³/s
\(Q_I\) Inglis (fan-shaped catchments) m³/s
\(q\) Dickens flood per km² m³/s

Method and standards

Flood formulas.

Where it is used

  • Preliminary bridge and culvert design.
  • Civil engineering examinations.

Common mistakes

  • Using the formulas outside their regions.
  • Entering area in hectares.

Assumptions and limits

  • Area in km²; Q in m³/s.

References

  • Classical engineering hydrology relations

Questions and answers

What peak flood for a 500 km² catchment?

About 1,206 m³/s by Dickens (C 11.4), 428 m³/s by Ryves (C 6.8) and 2,744 m³/s by Inglis.

Why are these only preliminary?

Area alone cannot capture rainfall, shape, slope or return period.

What do the defaults represent?

An illustrative 500 km² catchment with Dickens constant 11.4 and Ryves constant 6.8.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.