Worked example
Example: Illustrative round-ended piers. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Depth downstream of the bridge | 3.0000 m |
| Mean velocity downstream | 1.8000 m/s |
| Share of the flow area blocked by the piers | 12.000 % |
| Pier shape | Semicircular nose and tail (0.9) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Froude number downstream | 0.33186 |
| Afflux (rise upstream) | 102.59 mm |
Open this example in the calculator and change any input.
Formula
\(\Delta y = 2K\left(K + 10Fr_3^2 - 0.6\right)\left(\alpha + 15\alpha^4\right)Fr_3^2\,y_3\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_3\) | Depth downstream of the bridge | m |
| \(V_3\) | Mean velocity downstream | m/s |
| \(\alpha\) | Share of the flow area blocked by the piers | - |
| \(K\) | Pier shape | - |
| \(Fr_3\) | Froude number downstream | - |
| \(\Delta y\) | Afflux (rise upstream) | m |
Method and standards
Yarnell afflux.
Where it is used
- Flood levels upstream of bridges.
- Checking freeboard of bridge decks.
Common mistakes
- Using upstream instead of downstream depth.
- Applying it to pressure flow under the deck.
Assumptions and limits
- Subcritical flow; class A flow through the piers.
References
- Yarnell pier backwater equation
Questions and answers
What is afflux?
The rise of the water surface upstream of a bridge caused by the obstruction of piers and abutments.
Does pier shape matter?
Yes: square piers give about 40 % more afflux than rounded ones.
What do the defaults represent?
An illustrative bridge with 3 m downstream depth at 1.8 m/s and round-ended piers blocking 12 % of the flow area.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Yarnell, Bridge piers as channel obstructions, USDA Technical Bulletin 442 (1934)