FireCADCalc

Reflux Drum Size from Hold-Up Time

Volume, diameter and length of a horizontal reflux drum from the reflux and distillate liquid flows, hold-up time, fill fraction and length-to-diameter ratio.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserTank and drum

Inputs

Examples: 30 m3/h, 5 min, half full, L/D 310 m3/h, 10 min

Results

Liquid hold-up2.5000m³
Drum volume5.0000m³
Diameter1.2850m
Length3.8551m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 m3/h, 5 min, half full, L/D 3. The inputs, in the units selected above:

InputValue
Reflux + distillate liquid flow30.000 m³/h
Hold-up time (normal to empty)5.0000 min
Liquid fill at normal level (volume fraction)50.000 %
Length to diameter ratio3.0000 -

Applying the formula below gives:

ResultValue
Liquid hold-up2.5000 m³
Drum volume5.0000 m³
Diameter1.2850 m
Length3.8551 m

Open this example in the calculator and change any input.

Formula

\(V_L = \dot V_L t_h, \quad V = \frac{V_L}{\phi}, \quad D = \sqrt[3]{\frac{4V}{\pi(L/D)}}\)

Variables

Symbol Meaning SI unit
\(\dot V_L\) Reflux + distillate liquid flow m³/s
\(t_h\) Hold-up time (normal to empty) s
\(\phi\) Liquid fill at normal level (volume fraction) -
\(L/D\) Length to diameter ratio -
\(V_L\) Liquid hold-up m³
\(V\) Drum volume m³
\(D\) Diameter m
\(L\) Length m

Method and standards

Hold-up definition and cylinder geometry.

Where it is used

  • Overhead system design.

Common mistakes

  • Basing hold-up on distillate only.
  • Forgetting vapour space.

Assumptions and limits

  • Cylinder only; heads ignored.
  • φ is the liquid volume fraction. In a horizontal drum the level and volume fractions are equal only at half full; convert a level fraction to volume with the segment geometry before entering it.

References

  • Vessel volume from hold-up time (definition); typical hold-up times and L/D are design choices

Questions and answers

What hold-up time is usual?

About 5 minutes on reflux plus distillate for a level-controlled drum; more if it feeds a downstream unit.

Why only half full?

Room above the liquid lets vapour and inerts separate and the level swing.

Does it include heads?

No: the cylinder only; heads add a little volume.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.