Worked example
Example: Three components. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Component 1: feed mole fraction | 30.000 % |
| Component 1: K-value y/x | 3.0000 - |
| Component 2: feed mole fraction | 30.000 % |
| Component 2: K-value y/x | 1.2000 - |
| Component 3: feed mole fraction | 40.000 % |
| Component 3: K-value y/x | 0.30000 - |
| Component 4: feed mole fraction | 0 % |
| Component 4: K-value y/x | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour fraction | 40.000 % |
| Component 1: liquid mole fraction | 16.667 % |
| Component 1: vapour mole fraction | 50.000 % |
| Component 2: liquid mole fraction | 27.778 % |
| Component 2: vapour mole fraction | 33.333 % |
| Component 3: liquid mole fraction | 55.556 % |
| Component 3: vapour mole fraction | 16.667 % |
| Component 4: liquid mole fraction | 0 % |
| Component 4: vapour mole fraction | 0 % |
Open this example in the calculator and change any input.
Formula
\(\sum_i \frac{z_i (K_i - 1)}{1 + \frac{V}{F}(K_i - 1)} = 0, \quad x_i = \frac{z_i}{1 + \frac{V}{F}(K_i - 1)}, \quad y_i = K_i x_i\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(z_{1}\) | Component 1: feed mole fraction | - |
| \(K_{1}\) | Component 1: K-value y/x | - |
| \(z_{2}\) | Component 2: feed mole fraction | - |
| \(K_{2}\) | Component 2: K-value y/x | - |
| \(z_{3}\) | Component 3: feed mole fraction | - |
| \(K_{3}\) | Component 3: K-value y/x | - |
| \(z_{4}\) | Component 4: feed mole fraction | - |
| \(K_{4}\) | Component 4: K-value y/x | - |
| \(V/F\) | Vapour fraction | - |
| \(x_{1}\) | Component 1: liquid mole fraction | - |
| \(y_{1}\) | Component 1: vapour mole fraction | - |
| \(x_{2}\) | Component 2: liquid mole fraction | - |
| \(y_{2}\) | Component 2: vapour mole fraction | - |
| \(x_{3}\) | Component 3: liquid mole fraction | - |
| \(y_{3}\) | Component 3: vapour mole fraction | - |
| \(x_{4}\) | Component 4: liquid mole fraction | - |
| \(y_{4}\) | Component 4: vapour mole fraction | - |
Method and standards
Rachford–Rice.
Where it is used
- Flash drums and separators.
- Condensate and LPG systems.
Common mistakes
- K-values at the wrong temperature.
- Unnormalised feed.
Assumptions and limits
- Constant K at the flash conditions.
- For an all-liquid or all-vapour result the other phase's fractions are incipient values (K z or z/K), not normalised; they do not add to 1.
References
- Rachford and Rice (1952) equation Σ z_i(K_i − 1)/(1 + V(K_i − 1)) = 0
Questions and answers
30/30/40 % with K 3, 1.2 and 0.3?
About 40 % vaporises.
Where do K-values come from?
A K chart, Raoult's law (p_sat/p) for ideal mixtures, or a simulator.
Why check bubble and dew first?
Outside them the equation has no root between 0 and 1.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.