FireCADCalc

Minimum Reflux Ratio of a Binary Column (Pinch at the q-Line)

Minimum reflux ratio of a binary distillation with constant relative volatility from the pinch where the q-line meets the equilibrium curve, and a design reflux.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Saturated liquid feedPart-vaporised feed q = 0.5Sub-cooled feed q = 1.2

Results

Assumes the pinch is at the feed (no tangent pinch), constant α and constant molal overflow.

Pinch liquid composition29.216%
Pinch vapour composition50.784%
Minimum reflux ratio2.0500
Design reflux ratio2.6651

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Saturated liquid feed. The inputs, in the units selected above:

InputValue
Relative volatility2.5000 -
Feed (light component mole fraction)40.000 %
Distillate purity95.000 %
Feed condition q (1 saturated liquid, 0 saturated vapour)1.0000 -
Design reflux multiple1.3000 -

Applying the formula below gives:

ResultValue
Pinch liquid composition40.000 %
Pinch vapour composition62.500 %
Minimum reflux ratio1.4444
Design reflux ratio1.8778

Open this example in the calculator and change any input.

Formula

\(y = \frac{\alpha x}{1 + (\alpha - 1)x}, \quad y = \frac{q}{q - 1}x - \frac{x_F}{q - 1}, \quad R_{min} = \frac{x_D - y^*}{y^* - x^*}\)

Variables

Symbol Meaning SI unit
\(\alpha\) Relative volatility -
\(x_F\) Feed (light component mole fraction) -
\(x_D\) Distillate purity -
\(q\) Feed condition q (1 saturated liquid, 0 saturated vapour) -
\(R/R_{min}\) Design reflux multiple -
\(x^*\) Pinch liquid composition -
\(y^*\) Pinch vapour composition -
\(R_{min}\) Minimum reflux ratio -
\(R\) Design reflux ratio -

Method and standards

McCabe–Thiele pinch.

Where it is used

  • Column design and debottlenecking.
  • Solvent recovery columns.

Common mistakes

  • Using it for azeotropes.
  • Wrong q for the feed state.

Assumptions and limits

  • Constant α and molal overflow.
  • The design multiple R/R_min is at least 1.

References

  • McCabe–Thiele: pinch at the intersection of the q-line and the equilibrium curve y = αx/(1 + (α − 1)x); R_min = (x_D − y*)/(y* − x*)

Questions and answers

α 2.5, x_F 0.4, x_D 0.95, saturated liquid feed?

Pinch at x 0.4, y 0.625: R_min 1.44.

Design reflux?

Usually 1.1–1.5 × R_min, set by energy versus column cost.

Non-ideal mixtures?

A tangent pinch can occur above the feed; plot the curve.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.