Worked example
Example: D 40, F 100 kmol/h, R 2, liquid feed. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Distillate | 40.000 kmol/h |
| Feed | 100.00 kmol/h |
| Reflux ratio L/D | 2.0000 - |
| Feed condition q | 1.0000 - |
| Latent heat of the overhead vapour | 32.000 kJ/mol |
| Latent heat of the bottoms | 38.000 kJ/mol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reflux | 80.000 kmol/h |
| Vapour to the condenser | 120.00 kmol/h |
| Liquid in the stripping section | 180.00 kmol/h |
| Boil-up | 120.00 kmol/h |
| Condenser duty | 1,066.7 kW |
| Reboiler duty | 1,266.7 kW |
Open this example in the calculator and change any input.
Formula
\(L = RD, \quad V = (R + 1)D, \quad L' = L + qF, \quad V' = V - (1 - q)F, \quad Q_C = V\lambda_D, \quad Q_R = V'\lambda_B\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Distillate | mol/s |
| \(F\) | Feed | mol/s |
| \(R\) | Reflux ratio L/D | - |
| \(q\) | Feed condition q | - |
| \(\lambda_D\) | Latent heat of the overhead vapour | J/mol |
| \(\lambda_B\) | Latent heat of the bottoms | J/mol |
| \(L\) | Reflux | mol/s |
| \(V\) | Vapour to the condenser | mol/s |
| \(L'\) | Liquid in the stripping section | mol/s |
| \(V'\) | Boil-up | mol/s |
| \(Q_C\) | Condenser duty | W |
| \(Q_R\) | Reboiler duty | W |
Method and standards
Section balances with constant molar overflow.
Where it is used
- Utility sizing for columns.
- Steam and cooling water budgets.
Common mistakes
- Using mass latent heats with molar flows.
- Ignoring feed vapour.
Assumptions and limits
- Total condenser; saturated reflux.
- Inputs that give a negative stripping liquid L' or boil-up V' are rejected.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 13 (distillation)
- constant molar overflow and feed condition
Questions and answers
Why does a vapour feed cut the reboiler duty?
Vapour in the feed adds to the rectifying section, so less boil-up is needed: V' = V − (1 − q)F.
Are latent heats molar?
Yes, in J/mol; constant molar overflow assumes they are nearly equal.
What about sensible heat?
Neglected; add it for subcooled reflux.