Worked example
Example: 20 stages at 75 %, 600 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Theoretical stages in the column (reboiler excluded) | 20.000 - |
| Overall tray efficiency | 75.000 % |
| Tray spacing | 600.00 mm |
| Top allowance | 1.2000 m |
| Bottom (sump) allowance | 2.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Actual trays (rounded up) | 27.000 |
| Tower height (tangent to tangent) | 18.800 m |
Open this example in the calculator and change any input.
Formula
\(N_a = \left\lceil\frac{N_t}{E_O}\right\rceil, \quad H = (N_a - 1)S_T + H_{top} + H_{bot}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N_t\) | Theoretical stages in the column (reboiler excluded) | - |
| \(E_O\) | Overall tray efficiency | - |
| \(S_T\) | Tray spacing | m |
| \(H_{top}\) | Top allowance | m |
| \(H_{bot}\) | Bottom (sump) allowance | m |
| \(N_a\) | Actual trays (rounded up) | - |
| \(H\) | Tower height (tangent to tangent) | m |
Method and standards
Overall efficiency definition and tray stacking.
Where it is used
- Preliminary tower layout.
Common mistakes
- Dividing the reboiler stage by efficiency.
- Forgetting feed and manway spacing.
Assumptions and limits
- Uniform spacing; allowances from the user.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 14 (equipment for distillation and gas absorption)
- overall efficiency and Table 14-12 (representative tray efficiencies)
Questions and answers
Why exclude the reboiler?
It is a theoretical stage but not a tray.
What efficiency is usual?
60–90 % for most distillations; absorbers can be far lower.
Why round up?
Trays are whole; round up after dividing by efficiency.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.